Connecting the pump to the ecu, Es on – Garmin GHP 10 User Manual

Page 24

Advertising
background image



GHP 10 Marine Autopilot System Installation Instructions

4. Disconnect the hydraulic lines from the steering system where appropriate.
5. Use the diagram above to identify the connectors on the pump.
6. Remove the plugs from the five connections on the pump labeled C1, C2, H1, H2, and Tank.
7. Route hydraulic hose from the helm to the pump, and from the cylinder to the pump. Be sure to route three hoses to the helm, one

for port, one for starboard, and one for the return line. Add hose if needed.

8. Use the correct connectors to connect the hoses to the pump.

The C1 and C2 ports on the pump are SAE #6 straight-thread O-ring ports, and the H1, H2, and Tank ports are SAE #4 straight-

thread O-ring ports. Do not attempt to thread male pipe-thread fittings into these ports.
The pre-installed fittings adapt from straight-thread O-ring port to female pipe-thread. If needed, male pipe thread to male

straight thread fittings are also included with the pump. Use the included fittings only if they are applicable to your hydraulic

fitting configuration.
In alternative installations (see

page 23

) where the helm and cylinder hoses tee together externally and connect to the H ports,

the C ports will remain plugged. If port size is a concern, the plugs can be moved to the H ports and helm and cylinder hoses

can tee into the C ports, as the C ports use the larger SAE #6 fitting.

9. Connect the hoses to the helm and to cylinder.
10. You must bleed the hydraulic system, but wait until after you install the Shadow Drive. See

page 34

for more information on

bleeding the hydraulic system.

note: The pump may vibrate the hydraulic lines and cause noise when the autopilot is running. To eliminate the noise, secure the

hydraulic lines to a solid surface.

Connecting the Pump to the ECu

Do not connect the pump to the ECU until you have mounted the ECU to the boat following the procedures on

page 25

.

Configuring the Compact 2.1 L Pump for an Unbalanced-Cylinder Steering Configuration

The compact 2.1 L pump is factory-configured for use with a balanced-cylinder steering configuration. If necessary, it can be

configured to work with an unbalanced-cylinder steering configuration. If you are unsure of the cylinder steering configuration of your

boat, consult the boat manufacturer.
note: The following steps are necessary only if your boat has an unbalanced-cylinder steering configuration. Be sure to follow these

steps before bleeding the hydraulic system. If you remove the check valves after bleeding the hydraulic system, you will need to bleed

it again.

Notice

Keep all parts clean and free of dust and debris while configuring the pump for an unbalanced-cylinder steering system.

1. Remove the check valves from the pump manifold.
2. Pull the pistons out of the pump manifold. Take note of the piston orientation

as you remove them; you will need to reverse them as part of these

procedures.

3. Remove the Teflon rings.
4. Reverse the direction of the Pistons and reinsert them in the pump manifold.
5. Reinstall the check valves on the pump manifold.

Balanced configuration

Unbalanced configuration

Reversing the Pump Pistons for an

Unbalanced-cylinder Configuration

Check valves

Pistons

Teflon rings

Removing the Check Valves and Pistons

(Pistons Shown in a Balanced Configuration)

Check valves

Pistons

Teflon rings

Removing the Check Valves and Pistons

(Pistons Shown in a Balanced Configuration)

Advertising
This manual is related to the following products: