Appendix, Specifications, Physical – Garmin GHP 10 User Manual

Page 40: Power, 2l/2.0l pump, Compact 2.1l pump, Specifications ecu

Advertising
background image

0

GHP 10 Marine Autopilot System Installation Instructions

Appendix

Specifications
ECu

Physical

Dimensions (W×H×D): 6

19

/

32

Ч 4

19

/

32

Ч 2 in. (167.6 Ч 116.8 Ч 50.8 mm)

Weight: 1.5 lb. (0.68 kg)
temperature Range:

from 5°F to 131°F (from -15°C to 55°C)

Case Material: Fully gasketed, high-impact aluminum alloy, waterproof to IEC 529 IPX7 standards
Power Cable Length:

9 ft. (2.7 m)

Power

Input Power:

11.5–14 Vdc prior to serial number 19E002748

11.5–28 Vdc after serial number 19E002748 (only with CCU software version 2.70 or later)

Fuse:

40 A

Main Power Usage:

1 A (not including the pump)

CCu

Physical

Dimensions:

3

19

/

32

in. diameter (91.4 mm)

Weight: 5.6 oz. (159 g)
temperature Range:

from 5°F to 131°F (from -15°C to 55°C)

Case Material: Fully gasketed, high-impact plastic alloy, waterproof to IEC 529 IPX7 standards
CCU/ECU Interconnect Cable Length:

16 ft. (5 m)

Power

nMeA 2000 Power Input: 9–16 Vdc
nMeA 2000 Len:

2 (100 mA)

1.2L/2.0L Pump

Physical

Dimensions (W×H×D): 11 Ч 4

11

/

16

Ч 3

11

/

16

in. (279.4 Ч 119.4 Ч 94 mm)

Weight: 8.05 lb. (3.65 kg)
temperature Range:

From 5°F to 131°F (from -15°C to 55°C)

Cable Length: 19 in. (0.5 m)

Power

Main Power Usage:

Varies based on hydraulic loading

Compact 2.1L Pump

Physical

Dimensions (W×H×D): 16

1

/

2

Ч 6 Ч 7

1

/

2

in. (420 Ч150 Ч 190 mm)

Weight: 17.6 lb. (8 kg)
temperature Range:

From 5°F to 131°F (from -15°C to 55°C)

Cable Length: 19 in. (0.5 m)

Power

Main Power Usage:

Varies based on hydraulic loading

Advertising
This manual is related to the following products: