TROUBLESHOOTING

SYMPTOM

Machine not operating

(continued)

Electrical machine shut

down

POSSIBLE CAUSES

Thermal overload in motor

has tripped

No power to machine

Motor and/or pump not oper-

ating properly

Alarm condition has turned

OFF machine

Alarm condition has turned

OFF machine

External control or permeate

purge control contacts have

been shut machine down

REMEDIES

Allow the machine to cool:

check the feed water supply

and/or amp draw to the

motor.

Check the fuses or circuit

breakers, measure the

voltage.

See Tonkaflo pump instruc-

tions. Contact GE

Osmonics for possible repair

or replacement.

Check for minimum inlet

pressure and push alarm

reset switch.

Restart the machine by

pushing the alarm bypass.

Check for possible alarm

conditions: inlet pressure or

motor starter overload.

Check for proper orientation

of control contacts. Restart

machine manually or wait

for automatic start-up.