Installation continued – Garland 2000 User Manual

Page 6

Advertising
background image

Part # 4520414 (01/28/08)

Page 6

DO NOT under any circumstances; connect the vent stack

of the oven directly to the flue pipe or a vent system . If this

is done, it seriously decreases the efficiency and will cause

uneven heating of the section . If an outside flue connection

must be made, a suitable hood placed 12” (05mm) above

the oven flue must be provided to prevent direct suction of

the air through the oven sections .

Steam Injection (Optional Extra)

Steam is often used for baking of hard rolls, French bread,

Vienna bread and other hard crust breads . The steam

provided inside the oven is a cloud of atmospheric steam or

water vapor .

One quarter broiler h .p . for each bake deck is required at

the steam inlet of the deck . It is important that the steam

provided to the oven is lower pressure ( lbs . To 5 lbs per

square inch), (2100 kg/m² to 500 kg/m²) and condensate

must be drained from the steam line before it enters the

oven .

The steam will be sufficiently saturated at this pressure to

provide the vapor cloud effect that is needed to cover the

top of the product .

When steam is required in the deck, it is recommended that

the steam valve at the deck is only open a half-turn for 

to 5 seconds . The time will be determined by the operator .

Allowing too much steam to enter the oven will produce a

soggy product .

INSTALLATION Continued

Electrical Connections

The installation and connection should comply with current

codes . In Canada - The Canadian Electrical Code Part 1 and/or

local codes . In the U .S .A . - The National Electrical Code ASNA/

NFPA - current edition .

Before attempting the electrical connection, the rating

plate should be checked to ensure that the unit’s electrical

characteristics and the supply characteristics agree .

The unit has been wired as specified on the factory order

and the rating plate is stamped with the information . If it is

necessary to change the phase, refer to the wiring diagram

attached to the main terminal block, or refer to the rating

plate .

Electrical connection may be made though the knockout at

the rear of bottom of the unit to the terminal block located

directly behind the switch panel on the main bottom . Hinge

switch panel open .

For the supply connection use suitable wire for 60° C .

Break-In Procedure

It is strongly recommended that the 2000 Series ovens

supplied with core plates be put through a break-in period

to eliminate possible warpage of the core plates caused by

moisture absorption .

This action need only be carried out once providing the

ovens are used daily, however, if the ovens are left idle for an

extended period of time allowing the core plates to absorb

moisture, the following procedure must be again carried out .

Turn the top and bottom heat selector switched to HI, set the

thermostat to 00°F (149°C) maximum and allow the oven to

operate (without any product in the oven), for approximately

8 hours .