BEFORE YOU CALL FOR SERVICE…

Problem

Possible Causes

What To Do

Water contains tiny

New filter cartridges contain

• Turn on a water faucet and allow these harmless carbon particles to

black particles

activated carbon, which is

purge from the cartridge. Turn off the faucet when the water is clear.

a harmless black powder.

Water has air bubbles

Air in system after installation.

• Will go away after water runs for a while.

and is cloudy

Indicator light on the

Three months usage has occurred.

• Replace filter cartridge and batteries in the timer.

timer is flashing

This is the maximum life of the

• Reset timer by holding down the reset button for 5 seconds.

filter cartridges.

Indicator light on the

Timer operating normally.

• Light flashed 5 times when reset. It will not flash again until 3 months

timer is not working

have passed.

• No action required.

Batteries may need to be

• Observe orientation markings on the holder and install correctly.

replaced or they may have been

Replace batteries if they are old.

installed incorrectly.

Timer not reset

Reset button has built-in time delay.

• Reset timer by holding down reset button for 5 seconds.

Chlorine taste and /or

The filter cartridge is no

• Replace FXHTC filter cartridge.

odor in the product water

longer removing chlorine
from the water supply.

FXHSC Filter (pleated paper) is

• If chlorine reduction is desired, change to FXHTC filter cartridge.

installed, which does not remove
chlorine.

Fittings are leaking

Not enough sealing tape

• Unscrew fitting from head and remove old sealing tape. Add new sealing

between fitting and head

on fittings.

tape to the fitting.

Fitting has become loose.

• Install mounting bracket if not used.

• Tighten fittings with wrench.

Water dispenses

The filter has been installed

• A three-month change-out period is recommended.

very slowly

for too long.

Replace filter cartridge.

The filter cartridge has

• High sediment levels can cause premature clogging.

become clogged.

Replace filter cartridge.

Fittings are leaking

Piping system is not

• This fitting is designed for 3/4

″

copper pipe only. Consult a licensed

between fitting and pipe

3/4

″

copper pipe.

plumber if other piping is used.

Compression nut has become loose.

• Tighten the compression nut with wrench while holding other half of

fitting with second wrench.

Canister is difficult

Inlet water supply still on.

• Shut off inlet water and push red pressure relief button.

to remove

Internal water pressure has not

• Push red pressure relief button.

been relieved.

Leaking between

Seal O-ring is missing or damaged.

• Replace O-ring (Part #HDRING)

canister and head

Canister is loose.

• Turn off water supply.

• Press red pressure relief button.

• Tighten canister with canister wrench.