Service

Air Cap/Nozzle/Resistor Stud
Replacement (continued)

6.

Trigger the gun while installing the fluid nozzle (21)
and resistor stud (22) assembly with the multi-tool
(62). Tighten until the fluid nozzle seats in the gun
barrel.

7.

Install the air cap assembly (1, 2, 8). Test the gun
resistance as instructed on page 21.

06449

Fig. 11

20

2

1, 8

21

22

25

D

62



Apply a very light coat of lubricant



Tighten 1/8 to 1/4 turn past hand tight





0444A

21

22

62

Fig. 12





Torque to 10 in-lbs (1.12 N

S

m)

Electrode Replacement

1.

Prepare the gun for service as instructed on page
24.

1.

Remove the air cap, nozzle and resistor stud as
instructed on page 24.

2.

Unscrew and remove the fluid needle/electrode
(20) with the multi-tool (62). Hold the needle shaft
end to prevent it from turning. See Fig. 13.

CAUTION

Be careful not to damage the contact wire when
removing the electrode from the gun.

3.

Apply low-strength (purple) Loctite

r

or equivalent

thread sealant to the electrode and needle shaft
threads. Install the electrode finger-tight. Do not
overtighten it.

CAUTION

To avoid damaging the plastic threads or contact
wire, be very careful when installing the electrode.

4.

Install the fluid nozzle, resistor stud, and air cap
assembly as instructed at left.

5.

Test the gun resistance as instructed on page 21.

06624

Fig. 13

62

20





Apply low-strength (purple) Loctite or equivalent to needle shaft
threads