9.

Hold gun against mate-
rial pail. Take trigger
safety OFF. Turn pres-
sure control up until
motor begins to drive
pump. Trigger gun until
flushing fluid appears.

10. Move gun to flushing

pail, hold gun against
pail, trigger gun to thor-
oughly flush system.
Release trigger and put
trigger safety ON.

11. Turn prime valve down

and allow flushing fluid
to circulate for approxi-
mately 20 seconds to
clean drain tube.

12. Raise siphon tube above

flushing fluid and run
sprayer for 15 to 30 sec-
onds to drain fluid. Turn
pump switch OFF. Turn
engine OFF.