Connecting the lock to the opener control board – Mighty Mule FM143 User Manual

Page 8

Advertising
background image

7

Connecting the Lock to the Opener Control Board:

Step 1. Turn control box power switch OFF and unplug the transformer or disconnect the solar panel. Remove

control box cover and disconnect battery lead wires from the battery terminals before wiring the lock

board to the opener control board.

Step 2. Connect the WHITE wire (included) to Terminal #1 on the lock board. Connect the RED battery lead

wire (included) to Terminal #5 on the lock board. Connect the BLACK Battery lead wire (included) to

Terminal #2 on the lock board. (See Wiring Chart below). DO NOT connect lock board battery lead

wires to battery until Step 7!

PLEASE NOTE:

If a diagram of your control board is not pictured on page 8 or

10 please call the GTO ServiceDepartment at (800) 543-1236

or (850) 575-4144 for assistance.

Step 3. Attach the RED control board battery lead wire to one spade tongue on a double spade tongue connector

(included). Attach the BLACK control board battery lead wire to one spade tongue on the other double

spade tongue connector (included).

Step 4. Attach the Wire Connector. Place the WHITE wire from the lock board inside the “blocked” channel

on the Wire Connector. If the gate opens into the property (pull-to-open), place the BLACK wire from

the opener power cable inside the “through” channel on the Wire Connector. Crimp the Wire Connector

closed with pliers and fold plastic locking tab into place until it locks shut.

IMPORTANT: All Mighty Mule® and GTO/PRO® gate

opener control boards manufactured since March 2000,

have terminal strip wire connections (see Illustration H).

If your gate opener doesn't have terminal strip connec-

tors, you will need to follow the instructions for "Wiring

the Lock to Pre-March 2000 Gate Opener Control

Boards".

Terminal Strips

Illustration H

Wiring the Lock to Pre-March 2000 Gate Opener Control Boards

RED Wire To Battery

Positive (+) Terminal

RED Wire From Lock

BLACK Wire From Lock

WHITE Wire to

Motor Lead

BLACK Wire To Battery

Negative (–) Terminal

1 2 3 4 5

Lock Board

L o c k B o a r d

Wiring Chart

* Place a dab of petroleum

jelly on the terminal con-

tacts to prevent corrosion.

NOTE: If your gate opener control board has terminal wiring strips, skip to page 9 and follow the instruc-

tions for "Wiring the Lock to Gate Opener Control Boards with Terminal Strips".