Flexible aluminium pipes, corrosion-protected
sheet metal pipes and exhaust air pipes whose
material conforms to fire B1 in accordance with
DIN 4102 can be used. Exhaust air pipes should
have a nominal diameter of 150 mm.

Pay particular attention to ensuring

that

– the exhaust air ducts and pipes are kept as short

as possible

– the pipes are not laid at an acute angle, but as

bends and that they are inserted into the shaft at
an inclined upward angle and

– there are no cross-sectional constrictions in the

upward direction (this reduces the volume flow).

As standard, the blow-out opening of the wall hood
is in the upward direction.

To pass exhaust air through the outer wall, we
recommend the use of our telescopic wall box
TM 150-045 (Ø 150).

Note:
To prevent the ingress of water, e.g. condensate or
rain water from an uncovered exhaust air shaft, our
condensate separator RV 060-150 must be installed
in the exhaust air line. The condensate separator
must still be acciessible after installation.

Air recirculation

You need the following accessories to install the
air recirculation hood:

– KF 600-090: activated charcoal filter:

Depending on the ceiling height, the following duct
units are at your disposal for air recirculation:

– LK 600-110: Ventilation duct for a ceiling height

of 2.39 - 2.60 m

– LK 600-120: Ventilation duct for a ceiling height

of 2.61 - 3.00 m

The dimensions above refer to a distance of 1.60 m
from the floor to the bottom edge of the hood.

Exhaust air operation

Depending on the ceiling height, the following duct
units are at your disposal for exhaust air operation:

– LK 600-010: Ventilation duct for a ceiling height

of 2.27 to 2.60 m

– LK 600-020: Ventilation duct for a ceiling height

of 2.61 - 3.00 m

The dimensions above refer to a distance of 1.60 m
from the floor to the bottom edge of the hood.

If required, a side outlet for the air duct is available
at an extra charge.

The socket must be place behind the duct cover on
the wall.

13

520

260

15

0

480

1600

522.5

min.

600

over

e

lectric

cooker

min.

670

over

gas

cooker

Exhaust

air:

750

-

1400

Air

recirculation:

825

-

1400

Hood

height

Exhaust

air:

2

.35

-

3.0

Air

recirculation:

2

.43

-

3.0

Ceiling

height

Sus-
pension

Fig. 17