Laars heaters, Hayward heaters, Vsc pump address setting – Goldline LOGIC PL-P-4 User Manual

Page 17: Temperature sensors, Remote display/keypad, 500 ft max

Advertising
background image

Laars Heaters

1. Turn power off to heater.
2. Remove factory jumper from terminal block.
3. Wire Pro Logic to the heater as shown.
4. Ensure toggle switch is in the ON position.
5. Set heater thermostats to maximum position.

to limit switches

remove jumper

Fusible Link

white

white

Hayward Heaters

Refer to the instructions in the heater manual for “2-wire Remote Thermostat” operation under “Remote Control

Connections” and the diagram below:

1. Turn off power to heater.
2. Wire Pro Logic to terminals 1 & 2 (see diagram).
3. Leave jumper attached to terminals 4 & 5.
4. Move “BYPASS” dipswitch on heater circuit board to “ON” position (up).
5. Turn heater power back on.
6. Switch heater to either “Pool” or “Spa” (it doesn’t make any difference which is selected, the Pro Logic will take

control).

7. Heater display should be “bO” (for “bypass On).
8. Heater will fire whenever Pro Logic requests (when Pro Logic “Heater” LED is illuminated).

Do not remove jumper

Terminal block located at

electrical junction box

Dipswitch located on heater
circuit board

PK

W

R

BK

R

ON

ºC

OFF

ºF

14

VSC Pump Address Setting

For proper communications, a pump address must be set for each VSC used in the system. For single pump systems,

the VSC address should be set to 001. When using Dual Equipment, the Pool Filter pump should be set to 001 and

the Spa Filter pump should be set to 002. Refer to the TriStar Pump Owner’s Manual (IS3220VSC) and Hayward

document IS3220VSCAQLL for specific instructions on setting the pump address.

Temperature Sensors

The Pro Logic utilizes 10K ohm thermistor type sensors. Three sensors (water temperature, air temperature and solar

temperature) are included. If the Pro Logic is being used to control a solar heating system, the solar sensor is required.

The sensors are provided with a 15 ft. cable. See page 5 and the diagram below for installation information.

AIR

SENSOR

SOLAR/SPA

SENSOR

POOL/SPA

SENSOR

Remote Display/Keypad

The Pro Logic main unit can connect to a maximum of 3 remote wired display/keypads (ordered separately).

Use four conductor cable (typically phone cable) to connect the wired remote display/keypad with the Pro Logic

Control Center as shown below. The maximum wiring distance is 500ft. (160m). Note that the terminals on both the

Pro Logic main unit and the wired remote display/keypad are numbered: Connect 1 to 1, 2 to 2, etc. Refer to diagram

below.

Remote Display unit

Alternative

Concealed Wiring

1

2

3

4

500 ft max

3.75

4.50

If multiple remote display/keypads are installed: Never connect more than 2 wires to any terminal block. Two

remotes can be wired back to the Pro Logic main unit or the second display/keypad (and third, if applicable) can be

“daisy chained” with one display/keypad wired to the next. The maximum wire run from the Pro Logic main unit to the

furthest remote display/keypad is 500 ft (160m).