RS-232 INTERFACE

8

Binary Table

ASCII

Corresponding

RMT16-IR

Button

Binary

ASCII

Corresponding

RMT16-IR

Button

Binary

1

1

0011 0001

9

9

0011 1001

2

2

0011 0010

a

10

0110 0001

3

3

0011 0011

b

11

0110 0010

4

4

0011 0100

c

12

0110 0011

5

5

0011 0101

d

13

0110 0100

6

6

0011 0110

e

14

0110 0101

7

7

0011 0111

f

15

0110 0110

8

8

0011 1000

g

16

0110 0111

RS232 Settings

Bits per second ...................................................................................................... 19200

Data bits ......................................................................................................................... 8

Parity ....................................................................................................................... None

Stop bits ..........................................................................................................................1

Flow Control ............................................................................................................ None

Additional control of the EDID modes and IR channel are possible using the RS-232
interface. For any of these modes to be successfully written to the EEPROM, all Dip
Switches must be in the OFF position.

OK is printed out on screen when a mode has successfully been changed.