Troubleshooting – Generac 11400 User Manual

Page 11

Advertising
background image

Generac Portable Products PP5000T Generator

11

TROUBLESHOOTING

Problem

Engine is running, but no AC

output is available.

Engine runs good but bogs

down when loads are

connected.

Engine will not start; or starts

and runs rough.

Engine shuts down during

operation.

Engine lacks power.

Engine “hunts” or falters.

Cause

1. Circuit breaker is open.

2. Poor connection or defective cord

set.

3. Connected device is bad.

4. Fault in generator.

1. Short circuit in a connected load.

2. Generator is overloaded.

3. Engine speed is too slow.

4. Shorted generator circuit.

1. On/Off switch set to Off (o).

2. Dirty air cleaner.

3. Out of gasoline.

4. Stale gasoline.

5. Spark plug wire not connected to

spark plug.

6. Bad spark plug.

7. Water in gasoline.

8. Overchoking.

9. Low oil level.

10. Excessively rich fuel mixture.

11. Intake valve stuck open or closed.

12. Engine has lost compression.

1. Out of gasoline.

2. Low oil level.

3. Fault in engine.

1. Load is too high.

2. Dirty air filter.

3. Engine needs to be serviced.

1. Choke is opened too soon.

2. Carburetor is running too rich or

too lean.

Solution

1. Reset circuit breaker.

2. Check and repair.

3. Connect another device that is in

good condition.

4. Contact Generac service facility.

1. Disconnect shorted electrical load.

2. See “Don’t Overload the Generator”

on page 9.

3. Contact Tecumseh service facility.

4. Contact Generac service facility.

1. Set switch to On (–).

2. Clean or replace air cleaner.

3. Fill fuel tank.

4. Drain gas tank and fill with fresh

fuel.

5. Connect wire to spark plug.

6. Replace spark plug.

7. Drain gas tank; fill with fresh fuel.

8. Put choke lever to “no choke”

position.

9. Fill crankcase to proper level.

10. Contact Tecumseh service facility.

11. Contact Tecumseh service facility.

12. Contact Tecumseh service facility.

1. Fill fuel tank.

2. Fill crankcase to proper level.

3. Contact Tecumseh service facility.

1. See “Don’t Overload the Generator”

on page 9.

2. Replace air filter.

3. Contact Tecumseh service facility.

1. Move choke to halfway position till

engine runs smoothly.

2. Contact Tecumseh service facility.