4

120 Volt AC, 20 Amp Receptacles — May be used

to supply electrical power for the operation of 120 Volt

AC, 20 Amp, single phase, 60 Hz electrical lighting,

appliance, tool and motor loads.
120 Volt AC, 30 Amp Locking Receptacle — May

be used to supply electrical power for the operation of

120 Volt AC, 30 Amp, single phase, 60 Hz electrical

lighting, appliance, tool and motor loads.
120/240 Volt AC, 20 Amp Locking Receptacle —

May be used to supply electrical power for the

operation of 120 and/or 240 Volt AC, 20 Amp, single

phase, 60 Hz AC electrical lighting, appliance, tool

and motor loads.
Air Filter — This engine assembly filters air entering

the engine.
Circuit Breakers (AC) — Each receptacle is

provided with a circuit breaker to protect the

generator against electrical overload. Breakers are

"push to reset" type.

Fuel Shut Off Valve — Controls fuel supply to

engine.
Fuel Tank — Capacity of 4 U.S. gallons.
Grounding Wing Nut — Provides a tie-point for

connecting the generator frame to earth ground.
Run/Stop Switch — Must be in “Run” position to start

engine. Set to “Stop” to stop a running engine.

SPECIFICATIONS

Rated Maximum Continuous

Wattage Capacity

5000 Watts

Power Factor

1.0

Rated Maximum Continuous Load Current

At 120 Volts

41.67 Amps

At 240 Volts

20.83 Amps

Phase

1-phase

Rated Frequency

60 Hertz

KNOW YOUR GENERATOR

Read this owner’s manual and safety rules before operating your generator.

Compare the illustrations with your generator to familiarize yourself with the locations of various controls and

adjustments. Save this manual for future reference.

Circuit Breakers (AC)

Fuel Tank

120 Volt AC, 30 Amp

Locking Receptacle

Run/Stop Switch

Air Filter

120/240 Volt AC, 20 Amp

Locking Receptacle

120 Volt AC, 20 Amp

Receptacles

Grounding Wing Nut

Fuel Shut–Off Valve