Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
CPG036(048)0901D SINGLE PHASE 240V/60HZ DIRECT DRIVE
STATUS LIGHT
3 BLINKS
6 BLINKS
2 BLINKS
4 BLINKS
5 BLINKS
OFF
ON
1 BLINK
OPEN AUX. LIMIT
FALSE FLAME SENSED
OUTPUT DELAY
OPEN LIMIT SWITCH
COMPRESSOR
WITHOUT INDUCER ON
PRESSURE SWITCH
SWITCH
OPEN
OPEN ROLLOUT
SWITCH
IGNITION FAILURE
NORMAL OPERATION
NO POWER OR
INTERNAL CONTROL
EQUIP. STATUS
OR
OR
FAULT
BAD SWITCH
AUX. LIMIT OPEN
MAIN LIMIT OPEN
BAD SWITCH
3 MIN. COMP.
PRESSURE SWITCH
PRESSURE SWITCH
CHECK
CHECK
GAS PRESSURE
FLAME ROLLOUT
FLAME SENSOR
GAS VALVE
GAS FLOW
CHECK
-
208-240/1/60 0140L00506 REV A
BL
Y/Y2
YL
W
Y/Y2
BL
G
Y1
PK
WH
R
RD
C
YL
Y1
GR
C
2 STAGE COOLING
TB1
TB1
Y
C
W
Y2
G
R
C
Y1
STAT
STAT
 DIAGRAM ARE REPRESENTATIVE, BUT ACTUAL
 FACTORY SETTING MAY BE DIFFERENT BASED
 ON HEATING VALUE AND CAPACITY OF UNIT.
9. FOR LOW STAGE OPERATION ONLY, REMOVE
 WHITE JUMPER. FOR 2 STAGE OPERATION,
 REMOVE JUMPER AND CONNECT W2 TO W1
 ON THERMOSTAT.
SEE UNIT RATING PLATE FOR TYPE AND SIZE OF
OVERCURRENT PROTECTION.
8. TO RUN DIFFERENT SPEED FOR HEATING AND
 COOLING, DISCONNECT GEEEN JUMPER FROM
 "COOL" TERMINAL AND REPLACE WITH
 APPROPRIATE SPEED TAP. THEN PLACE
 DISCONNECTED END OF JUMPER ON
 "UNUSED" TERMINAL LEFT OPEN BY MOVING
 THE SPEED TAP.
2. FOR 208 VOLT TRANSFORMER OPERATION
 MOVE BLACK WIRE FROM TERMINAL 3 TO
 TERMINAL 2 ON TRANSFORMER.
1. REPLACEMENT WIRE MUST BE THE SAME
 SIZE AND TYPE OF INSULATION AS ORIGINAL.
 (USE COPPER CONDUCTOR ONLY).
AUXILIARY LIMIT SWITCH
FEMALE PLUG/CONNECTOR
INTEGRATED IGNITION CONTROL
LS
4
INSTALLER/SERVICEMAN
TO THERMOSTAT
TERMINAL BLOCK
G
R
5
7
9
IIC
Y1
W
Y2
3
6
12
10
8
11
RS
ALS
PS
PLF
C
NOTE
4
4
3
2
1
5
6
GV
C
CM
CONDENSER MOTOR
LS
LIMIT SWITCH
VENT MOTOR RELAY
VENT MOTOR
PRESSURE SWITCH
TERMINAL BLOCK (24V SIGNAL)
ROLLOUT SWITCH
VMR
VM
PS
PLF
TB1
RS
NOTES
CONTACTOR
GAS VALVE
IGNITOR
EQUIPMENT GROUND
FLAME SENSOR
EVAPORATOR MOTOR
FUSE
F
C
GV
FS
GND
IGN
IIC
EM
COMPRESSOR
COMPONENT LEGEND
COMP
ALS
TB1
TR
TRANSFORMER
HPS
LPS
LPS
LOW PRESSURE SWITCH
HPS
HIGH PRESSURE SWITCH
HIGH VOLTAGE
FACTORY WIRING
 OPTIONAL
 HIGH VOLTAGE
LOW VOLTAGE
FIELD WIRING
LINE VOLTAGE
LOW VOLTAGE
RD
Y1
G
R
W
NO ECONOMIZER
YL
RD
Y/Y2
W
WH
GR
R
GR
G
WH
WITH ECONOMIZER OPTION
C
THERMOSTAT
FIELD WIRING
BL
TB1
G
R
W
Y
C
W
R
G
STAT
BL/PK BLUE WITH PINK STRIP
YL/PK YELLOW WITH PINK STRIP
GR GREEN
WIRE CODE
BL BLUE
PU PURPLE
PK PINK
WH WHITE
BK BLACK
RD RED
BR BROWN
OR ORANGE
YL YELLOW
TB1
IIC
FS
TR
FS
F
IGN
2
1
3
3. FOR DIFFERENT THAN FACTORY SPEED TAP.
 CHANGE COOLING SPEED AT COOL
 TERMINAL. CHANGE HEATING SPEED AT
 HEAT TERMINAL ON CONTROL BOARD
BK - HIGH SPEED
BL - MED. SPEED
RD - LOW SPEED
3 SPEED
MOTOR
4. ACCESSORY ECONOMIZER PLUG ADJACENT
 TO BLOWER HOUSING IN RETURN AIR
 COMPARTMENT. REMOVE MALE PLUG AND
 ATTACH FEMALE PLUG TO ECONOMIZER
 ACCESSORY.
USE NEC CLASS 2 WIRE.
5. USE COPPER CONDUCTORS ONLY.
7. SPEED TAP TERMINATIONS SHOWN ON
6. PURPLE WIRE CONNECTS TO TRANSFORMER
 (PIN 1).
BLOWER CAPACITOR
BC
L2
L2
SUPPLY VOLTAGE
208-240/1/60
L1
C
T1
EM
C
R
S
H
C
CM
F
C
VM
LI
PCB
HEAT
COOL
FC
PCB
DI
RUN CAPACITOR FOR CONDENSER FAN
RCCF