Problem

Possible Causes

What To Do

Condensation

This usually happens when

This is normal. After the water in the tank warms

a new water heater is

up the condensation will disappear. If, however, the

filled for the first time.

condition persists, examine the piping and fittings
for possible leaks.

Moisture from the products

This is normal and will disappear in time. Excessive

of combustion condensing

condensation can cause pilot outage.

on the tank surface.

An undersized water

Use a water heater size that meets the requirements

heater will cause

of your needs.

condensation.

Yellow flame

Scale on top of the burner.

Call a qualified service technician to remove scale.

or soot

Flue or combustion air inlet

Remove obstruction or debris from flue or

openings are restricted.

combustion air inlet openings on jacket.

Not enough combustion or

Proper operation of the water heater requires air for

ventilation air supplied to

combustion and ventilation. See the Combustion and

the water heater location.

Ventilation Air information in the “Installing The Water
Heater” section of this manual.

Unable to light

Air in gas line.

Contact a qualified service technician to purge the air

the pilot

from the gas line.

Pilot orifice clogged.

The pilot should be cleaned or replaced by a qualified
service technician.

Pilot tube pinched or

The pilot should be cleaned, repaired or replaced by a

clogged.

qualified service technician.

Gas Cock Knob not

See the “Lighting The Water Heater” section of this

correctly positioned.

manual.

Pilot does not stay

Loose thermocouple.

The connection at the gas control (thermostat) should

lit when the RED

be tightened by a qualified service technician.

button is released

Thermocouple defective.

The thermocouple should be replaced by a qualified
service technician.

Safety magnet defective.

The gas control (thermostat) should be replaced by a
qualified service technician.

Gas control (thermostat)’s

The gas control (thermostat) should be replaced by a

single use gas shut-off

qualified service technician.

device has opened.

Combustion Shutoff Device

The combustion shutoff device should be replaced

Tripped.

by a qualified service technician

CAUTION:

For your safety DO NOT attempt repair of gas piping, gas control (gas control (thermostat)),

burners, vent connectors or other safety devices. Refer repairs to qualified service personnel.

!

Troubleshooting Tips

Save time and money! Review the charts on the following
pages first and you may not need to call for service.

This water heater incorporates a combustion shut off device that shuts the operation of the water heater
down if undesirable combustion conditions occur. Such as the presence of flammable vapors or blockage of
the combustion air inlet openings. Please contact a Qualified Service Technician if this occurs.

Safety Instructions