Grounding and Electric Requirements

WARNING

Your system must be grounded. Read

warnings, page 3.

The sprayer cord includes: a grounding wire with an

appropriate grounding contact.

Fig. 3

ti7480a

The sprayer requires:

110--120V units: 100--130 VAC, 50/60 Hz, 15A, 1

phase, circuit with a grounding receptacle.

240V Units: 210--255 VAC, 50/60 Hz, 7.5A, 1 phase,

circuit with a grounding receptacle.

Never use an outlet that is not grounded or an

adapter.

Fig. 4

ti7481a

Do not use the sprayer if the electrical cord has a

damaged ground contact. Only use an extension cord

with an undamaged ground contact.

Fig. 5

ti7482a

Recommended extension cords for use with this

sprayer:

D

110--120V: 3--wire, 12 AWG (2.5 mm

2

) minimum,

300 ft. (90 m) maximum length.

D

240V: 3--wire, 16 AWG (1.0 mm

2

) minimum, 300 ft.

(90 m) maximum length.

Smaller gauge or longer extension cords may

reduce sprayer performance.

Spray gun: ground through connection to a properly

grounded fluid hose and pump.

Fluid supply container: follow local code.

Solvent and Oil--based fluids: follow local code. Use

only conductive metal pails placed on a grounded

surface such as concrete. Do not place the pail on a

nonconductive surface such as paper or cardboard,

which interrupts grounding continuity.

Grounding the metal pail: connect a ground wire to

the pail by clamping one end to pail and other end to

ground such as a water pipe.

To maintain grounding continuity when flushing

or relieving pressure: hold metal part of the spray

gun firmly to the side of a grounded metal pail, then

trigger the gun.

Fig. 6

ti7483a