SITE REQUIREMENTS

Position On Roof

Minimum Clearances

A

On ridge or within 600mm

600mm above ridge

B

Elsewhere on roof

2300mm horizontally from roof surface and:

a) 1000mm above highest point of flue exit from roof or

b) as high as the ridge

C

On pitched, within 2300mm horizontally to

openable window, dormer

1000mm above top of opening

D

Within 2300mm of another building

600mm above top of building

1. FLUE OUTLET POSITIONS

150mm

max

Vertical

Measurement

Terminal

Insulation

Flue

Horizontal

Measurement

Adjacent

Building

The vertical measurement is the lowest from either the

point of discharge or 150mm above insulation.

IMPORTANT: Seek

specialist advice if installing

in a dwelling with a

thatched roof

2. MINIMUM DIMENSIONS - HEARTH

2.1 The appliance must stand on a non-combustible

constructional hearth which is at least 125mm thick with

the minimum dimensions as shown in diagram. If it is to be

fitted in a raised setting consideration may need to be given

to extending the depth of the hearth to safely containing

any falling logs or embers.

2.2 The building must have a suitable load-bearing capacity for

the hearth and appliance.

• Consult a structural engineer for advice before proceeding

2.3 When fitting into an existing hearth check:

• That the appliance complies with current construction

regulations and is at least the minimum sizes shown

2.4 If there is no existing fireplace or chimney it is possible to

construct a suitable non-combustible housing and hearth

setting. The flue must be installed in accordance with all

local and national regulations and current rules in force .

• Check if adding a new chimney to your property requires

planning permission

2.5 Some houses are built using a timber frame construction

with high levels of thermal insulation. Isolate the appliance

from combustible materials, and provide sufficient

ventilation to maintain the heating efficiency.

Constructional hearth

1

Superimposed hearth

or

area to be free of

combustible material

Riva 40 Riva 55 Riva 66 Riva 66 Avanti Riva 76

RV40

RV55

RV66

RV66 AVC

RV76

A 792mm 932mm 1042mm

1042mm

1162mm