7. Take care when discharging air from the tank, i.e.

from the safety valve, the drain cock or the air outlet.

Compressed air can be extremely dangerous. Take care

the discharge air does not cause dust, stones or any

other foreign particles to be blown through the air and

that the air is discharged in a safe manner.

Troubleshooting

Trouble

Possible cause

Possible remedy

Motor will not run, running too

slow or becoming excessively hot

Power fault or supply voltage too low

Check the power supply

Power cord too long or too thin

Use authorised service centre

to replace the power cord

Faulty pressure switch

Use authorised service centre

to repair or replace the switch

Faulty motor

Use authorised service centre

to repair or replace the motor

Main compressor sticking/tight

Use authorised service centre

to repair or replace faulty parts

Main compressor sticking/tight

Moving parts damaged by heat

due to insufficient lubrication

Use authorised service centre to

check crankshaft, bearings, con rod,

piston rings, etc and replace

where necessary

Moving parts damaged or blocked

by foreign particle

Vibration or abnormal noise

Loose part

Use authorised service centre

to check and repair if necessary

Foreign body in main compressor

Use authorised service centre

to check and clean if necessary

Piston connecting with the valve seat

Use authorised service centre

to increase size of gasket

Moving parts excessively worn

Use authorised service centre

to repair or replace