5. Check daily the operation of the safety valve. This

check should be performed when the tank contains

close to max pressure in the tank.

To check the valve, pressurise the tank, and pull the ring

OUTWARDS on the safety valve.
Air should discharge from the valve.
Release the ring of the safety valve. When the ring is

released the air discharge must stop.

WARNINGS.

Safety glasses must be worn when performing this test.
Do not have your face close to the safety valve when

performing this test as air will discharge from the valve at

a high force.
If the safety valve does not operate correctly in any way

as described above, turn off the compressor immediately

and have the compressor and safety valve checked and

tested at an authorised Service centre.

DO NOT CONTINUE TO USE THE COMPRESSOR IN ANY

WAY IF THE SAFETY VALVE DOES NOT WORK AS ABOVE.

General inspection

1. Regularly check that all the fixing screws are tight.
2. The supply cord of the tool should be checked

frequently for damage. If damaged, have the cordset

replaced by an authorised service facility to avoid

a hazard.

Cleaning

1. Keep the tool’s air vents unclogged and clean at all

times.

2. Remove dust and dirt regularly. Cleaning is best done

with a soft brush or a rag.

3. Re-lubricate all moving parts at regular intervals.
4. If the body of the compressor needs cleaning, wipe it

with a soft damp cloth. A mild detergent can be used

but nothing like alcohol, petrol or other cleaning agent.

5. Never use caustic agents to clean plastic parts.

Caution.

Water must never come into contact with

the tool

Power cord maintenance

Only an authorised service centre should replace the

cordset or carry out other repairs. If the cordset is

damaged or worn, have it repaired or replaced by an

authorised service centre.