Service, Caution – Graco PT2500 User Manual

Page 19

Advertising
background image

820-133

19

Service

7.

Lubricate the screws (25) and then install and torque
them to 170–200 in–lb (19–23 N.m).

CAUTION

Whenever you remove the paint pump screws,
torque them as instructed above, and then retorque
them after 3 to 5 hours of operation.

8.

Check the hydraulic oil level and add Graco-ap-
proved oil as necessary until the level is 1 inch (25
mm) from the top of the plate. See Fig. 11.

9.

Turn the pressure control fully counterclockwise
(no pressure). Plug in the sprayer and turn it on. Run
the sprayer for two minutes to fill the hydraulic sys-
tem. Increase the pressure to maximum and turn the
sprayer on and off four times to help rid the hydraulic
system of air.

Fig. 15

21

22a

22b

26a

26

27

25

24

28d

28f

28c

28e

28b

28a

C

4

4a

38

37

36

66

35

3

67

20

28

18a

0284

1

3
4

2

Torque to 125–150 in–lb (14–17 N.m).

Apply sealant to the threads.

Lubricate the internal threads.

Torque to 125–150 in–lb (14–17 N.m).

Torque to 280–300 in–lb (32–34 N.m).

Lubricate the threads.

Torque to 320–360 in–lb (36–41 N.m).

Torque to 170–200 in–lb (19–23 N.m).

Do not alter the position of the nut.

The start switch is located
in the switch box.

5

7
8

6

10

1

2

3

2

4

5

6

7

10

8

6

9

9

Advertising