Ingle, Perator, Nstallation – GTO SL-1000B User Manual

Page 14

Advertising
background image

12

S

INGLE

G

ATE

O

PERATOR

I

NSTALLATION

O

VERVIEW

OF

O

PERATOR

I

NSTALLATION

G

ATE

P

REPARATION

Level

Plumb

Concrete

Concrete

Be sure the gate is properly installed and slides smoothly before installing the GTO/PRO Slide Gate Operator. The

gate must be plumb, level, and move freely. The gate must not bind or drag on the ground. Never use a wheel

on the gate, because the additional drag and resistance can cause the operator to obstruct.

The diagram below shows a single slide gate installation with recommended safety features. The operator must

be installed on the inside of the gate. GTO requires using safety edges and roller guards to help reduce the

possibility of bodily injury.

Chain

Contact Sensor

Roller Guard

Receiver

(cable in separate

conduit)

Roller Guard

CAUTION

AUTOMATIC GATE

STAND CLEAR

1-800-543-GATE

®

Operator

Contact Sensor

Contact Sensor

(REQUIRED)

(REQUIRED)

(REQUIRED)

(REQUIRED)

(REQUIRED)

Use PVC Conduit

(not included)

Run 1000' (max.) of low

voltage wire to control

box from transformer

(wire not included).

120 Volt Indoor

Transformer

(Surge Protector

not supplied)

Roller Guard

(REQUIRED)

Chain Bracket

Chain Bracket

for power cables.

1. KEEP CLEAR! Gate may move at any time.

2. Do not allow children to operate gate or

play in gate area.

3. This gate is for vehicles only. Pedestrians

must use a separate entrance.

Moving Gate Can Cause

Injury Or Death

WARNING

!

Advertising
This manual is related to the following products: