Rs-232 serial control – Gefen GEF-DVIKVM-848DL User Manual
Page 21
Advertising

18
RS-232 SERIAL CONTROL
#EDIDDSTOLO Function
The #EDIDDSTOLO function reads the downstream EDID and stores it to a Local
EDID input.
Syntax:
#EDIDDSTOLO param1 param2 [param3...param9]
Parameters:
param1
A downstream monitor
[1 - 8]
param2
Input
list
[1
-
8]
Notes
:
If param2 = 0, then the downstream EDID is stored to all 8 DVI inputs.
Examples
:
#EDIDDSTOLO 2 1 2 3 4 5
inputs 1-5 use display 2 EDID
#EDIDDSTOLO 3 0
all inputs use display 3 EDID
#EDIDDSTOBA Function
The #EDIDDSTOBA function reads the downstream EDID and stores it to a
specifi ed EDID bank.
Syntax:
#EDIDDSTOBA param1 param2
Parameters:
param1
A downstream monitor
[1 - 8]
param2
EDID
bank
offset
[1
-
5]