RS-232 SERIAL CONTROL
#LOCKPOWER Function
The #LOCKPOWER enables/disables the power lock state. Enabling this feature
will store the 5V status for each input prior to shutting the unit down. This pre-
serves the 5V state when the Matrix is restarted.
Syntax:
#LOCKPOWER param1
Parameters:
param1
State
[0
-
1]
Value
Meaning
0
Disable Power Lock
1
Enable Power Lock
#MASKOUT Function
The #MASKOUT function allows blanking or selected outputs.
Syntax:
#MASKOUT param1 param2
Parameters:
param1
Output
[1
-
8]
param2
Output
[1
-
8]
Notes:
The current masking state will be lost if power is lost.