Warning, Dc b a 5, Installation of the range – GE 164D3333P159 User Manual

Page 42

Advertising
background image

Installation of the range.

42

Operating Instructions

Installation Instructions

Safety Information

Tr

oubleshooting T

ips

Customer Service

Read these instructions completely and carefully.

4-Wire Power Cord Installation

WARNING:

The neutral wire of the supply circuit

is connected to the neutral terminal located in the center of the
connector block. The power leads must be connected to the outside
(brass colored) terminals. The 4th grounding lead must be connected
to the frame of the range with the grounding plate and grounding screw.

Remove the 3 screws from the connector block.

Remove the grounding screw and strap from the connector block middle
location and the screw connection to the frame of the range.

Insert screws through each power cord terminal ring and into connector
block until screw engages nut. Be certain that the center wire is connected
to the center screw of the connector block. Tighten screws securely.

Attach ground wire to the frame of the range.

d

c

b

a

5

Before

After

Neutral terminal

Ground Strap
(grounding to range)

Grounding to range

Grounding
plate

Neutral terminal