4 programming with #93d menu mode – Guardian Technologies Ademco VISTA-40 User Manual

Page 55

Advertising
background image

С 55 С

Section 4.

PROGRAMMING WITH #93 MENU MODE

General Information

NOTE: The following fields should be preset before beginning:
2*00 (Number of Partitions); 1*32 (receiver type). In addition,
receivers should be programmed via Device programming.

After programming all system-related programming fields in the usual way, press
#93 while still in programming mode to display the first choice of the menu driven
programming functions, which are as follows:

ZONE PROG?
0=NO 1=YES

For programming the following:
¥ Zone Number
¥ Zone Response Type
¥ Hardwired zone
¥ RF Zone
¥ Right/left Loop Zone
¥ Serial number RPM zone
¥ Partition Number for Zone
¥ Dialer report code for zone

SERIAL PROG?
0=NO 1=YES

For entering 5800 series transmitter & polling loop
device serial numbers into the system.

ALPHA PROG?
0=NO 1=YES

For entering alpha descriptors for the following:
¥ Zone Descriptors

¥ Partition Descriptors

¥ Installer's Message

¥ Relay Descriptors

¥ Custom Words

DEVICE PROG?
0=NO 1=YES

For defining the following device characteristics for
addressable devices, including keypads, RF
receivers (4281/5881) and 4204 output relay
modules:
¥ Device Address

¥ Keypad Options

¥ Device Type

¥ Phone Module

¥ Device's Home Partition

¥ VIM Module

RELAY PROG?
0=NO 1=YES

For defining output relay (or Powerline carrier)
functions.

RLY VOICE DESCR?
0=NO 1=YES

For entering voice descriptors to be used with
phone module functions.

CUSTOM INDEX #?
0=NO 1=YES

For creating custom word substitutes for phone
module annunciation.

QUIT MENU MODE?
0=NO 1=YES

Enter 1 to return to data field programming mode.
Enter 0 to display the next menu selection.

Press 0 (NO) or 1 (YES) in response to the displayed menu selection. Pressing 0
will display the next choice in sequence. Refer to the ÒZone ProgrammingÓ
section for instructions for programming zone characteristics, the ÒDevice
ProgrammingÓ section for instructions for programming addressable devices, and
the ÒAlpha ProgrammingÓ section for programming alpha descriptors. The
following is a list of commands used while in the menu mode.

#93 Menu Mode Key Commands

#93

Enters Menu mode

[*]

Serves as ENTER key. Press to have keypad accept entry.

[#]

Backs up to previous screen.

0

Press to answer NO

1

Press to answer YES

01Ð99

All entries are 2-digit entries.

00

Returns to the QUIT MENU MODE? prompt.

Advertising