Problem

Possible Causes

What To Do

Capacity display stays

Total system capacity was calculated

• As the water usage continues, the remaining capacity will drop

at “9999” even though

to be a value greater than 9999

below 9999, then other values will be shown.

there is water usage

Control does not respond Button is not active in the

• Wait for 30 seconds until lights begin to alternate.

to REGEN button

programming mode

Control does not display Transformer is unplugged

• Check connection to control and wall outlet.

time of day

No electric power at outlet

• Repair outlet or use a working outlet.

Defective transformer

• Replace transformer.

Defective circuit board

• Replace control.

Control does not display Outlet operated by a switch

• Use an outlet not controlled by a switch.

correct time of day

Power outage

• Reset time of day and replace battery.

No water flow display

Bypass valve in “bypass” position

• Set bypass valve into “service” position.

when water is flowing

Meter probe disconnected or not fully

• Fully insert probe into meter housing.

(colon doesn’t blink)

connected to meter housing

Restricted meter turbine rotation due

• Remove bypass valve, free up turbine and flush with clean

to foreign material in meter

water. Turbine should spin freely. If not, refer to the Water Meter
Maintenance
section.

Defective meter probe

• Replace control.

Defective circuit board

• Replace control.

Control display is frozen

Back to back regenerations were

• Refer to Manual Regeneration section.

at REGEN TIME REMAINING requested

Control regenerates at

Power outages

• Reset time of day to correct time of day and replace battery.

the wrong time of day

Time of day set incorrectly

• Reset time of day to correct time of day. Note PM light.

Time of regeneration set incorrectly

• Reset time of regeneration. Note PM light.

Cam gear stalled in

Motor not operating

• Replace motor assembly.

regeneration cycle

Motor runs backward

• Replace motor assembly.

No electric power at outlet

• Repair outlet or use a working outlet.

Broken gear

• Replace gear.

Defective switch

• Replace switch.

Binding of cam gear

• Remove foreign object obstruction from valve discs or cam

gear.

Water pressure greater than 125 psi

• Install pressure regulator to reduce pressure.

during regeneration

Defective circuit board

• Replace control.

Continuous regeneration. Defective switch

• Replace switch.

Cam gear does not stop
at the end of regeneration.

Control does not

Transformer unplugged

• Connect power.

regenerate automatically No electric power at outlet

• Repair outlet or use a working outlet.

or when REGEN button is

Defective motor

• Replace motor assembly.

pressed

Defective switch

• Replace switch.

Control does not

If water flow display is not operative,

• Refer to “No water flow display when water is flowing”

regenerate automatically refer to “No water flow display

in this table.

but does regenerate when when water is flowing” in this table
REGEN button is pressed
Incorrect hardness and capacity

• Set new control values. See the Programming the Control

settings

section.

Defective circuit board

• Replace control.