Installation instructions, Venting instructions (cont.) – GE GN75DNSRSA User Manual

Page 20

Advertising
background image

20

Installation Instructions

VENTING INSTRUCTIONS
(cont.)

VENT PRODUCTS

Ubbink

Telephone: 888.HOTWTER

(888.468.9837)

Heat-Fab

Telephone: 1.800.772.0739

Web Site:

www.heatfab.com

Metal-Fab Inc.

Telephone: 1.800.835.2830

1.316.943.2351

Web Site:

www.metal-fabinc.com

VENT MANUFACTURER CONTACT INFORMATION FOR INSTALLATION INSTRUCTIONS AND PARTS LIST

Listed and Tested Vent Products for GN75DNSRSA, GN94DNSRSA and GP94DNSRSA (concentric venting)

VENTING INSTRUCTIONS (cont.)

FLUE INSTALLATION – CONCENTRIC VENTING

To adjust the condensate collector position:

Loosen the 4 screws at the rear bracket.

Slide the bracket away from the female
vent top.

Remove the 4 screws attaching the female vent
top to the water heater.

Lift up the female vent top and reposition as
desired (or replace with a male vent top).

Install the 4 screws at the vent top and tighten
the 4 screws at the bracket.

Secure the first vent component to the water heater
with one self-tapping screw at the hole located above
the condensate collector.

5

4

3

2

1

Bracket

MANUFACTURER

PRODUCT

PARTS

Ubbink

Rolux Vent System

Refer to the manufacturer’s technical literature

Heat-Fab

Saf-T Vent SC system

for specific part numbers and instructions.

Metal-Fab

Corr/Guard Vent/

At the time of printing, these manufacturers’

Air Intake System

products were listed and tested vent products.
The installer must verify prior to installation if
proper venting is used. For up-to-date approved
vent materials, see http://directories.csa.international.org/
for the CSA Certification record with approved vent materials.

Advertising