Temperature limiting, Diagnostics check–for technician’s use only – GE 5500 User Manual

Page 7

Advertising
background image

7

www.GEAppliances.com

Temperature Limiting

Temperature limiting can reduce energy costs
by limiting the lowest temperature that can be
set for cooling and the highest temperature that
can be set for heating. Temperature limiting is
controlled by switches 1–6 on the second block

of auxiliary controls. The first three switches are
used to select the cooling limits. The next three
switches are used to control the heating limits.
This feature is not available with the Remote
Thermostat–Class 2.

Temperature limiting during COOL mode

(all temperatures shown in °F)

UP

DOWN

Minimum

Maximum

NONE

1, 2, 3

60°

85°

1

2, 3

64°

85°

1, 2

3

66°

85°

2

1, 3

68°

85°

2,3

1

70°

85°

1, 2, 3

NONE

72°

85°

1, 3

2

74°

85°

3

1, 2

76°

85°

Temperature limiting during HEAT mode

(all temperatures shown in °F)

UP

DOWN

Minimum

Maximum

NONE

4, 5, 6

60°

85°

4

5, 6

60°

80°

4, 5

6

60°

78°

5

4, 6

60°

76°

5,6

4

60°

74°

4, 5, 6

NONE

60°

72°

4, 6

5

60°

70°

6

4, 5

60°

65°

Safety Instructions

Operating Instructions

Care and Cleaning

Troubleshooting T

ips

Customer Service

Heat Boost

When this switch is enabled (UP) and outdoor
temperatures are between 25° F and 46° F, heat
pump only operation is locked out. This setting is
used to provide supplementary heat to the heat
pump operation in conditions where the heat
pump only operation is not sufficient to maintain
a consistent, comfortable room temperature to
the consumer.

Diagnostics Check–For Technician’s Use Only

When this switch is enabled (UP), the unit will go
through an operations check of all components,
which takes about 3 minutes (176 seconds).
This diagnostic tool is intended for use by
a qualified technician.

TL1 (C) (Temp. Limit 1–Cool)
TL2 (C) (Temp. Limit 2–Cool)
TL3 (C) (Temp. Limit 3–Cool)

TL1 (H) (Temp. Limit 1–Heat)
TL2 (H) (Temp. Limit 2–Heat)
TL3 (H) (Temp. Limit 3–Heat)

BOOST (Heat Boost Operation)

DIAGNOS (Diagnostic Check)