Pressure relief procedure, Grounding and electrical requirements – Graco RTX-650 User Manual

Page 6

Advertising
background image

Component Identification

6

311771D

Pressure Relief Procedure

To reduce risk of injury, follow this procedure
whenever you see this symbol throughout this
manual, Also, perform this procedure whenever
you:

• Stop spraying

• Check or repair any part of this system

• Install or clean spray nozzle

1.

Turn Power Switch OFF.

2.

Trigger gun into material hopper.

3.

Disconnect air gun.

Grounding and Electrical
Requirements

This sprayer must be grounded. Grounding reduces the
risk of electrical shock by providing an escape wire for
the electrical current. The sprayer cord includes a
grounding wire with an appropriate grounding plug. The
plug must be plugged into an outlet that is properly
installed and grounded in accordance with all local
codes and ordinances.

Check with a qualified electrician or if grounding
instructions are not completely understood, or if in doubt
as to whether the product is properly grounded. Do not
modify plug provided; if it will not fit the outlet, have
proper outlet installed by a qualified electrician.

120V AC Systems

• This equipment requires a 120V AC, 60 Hz, 15A

circuit with a grounding receptacle. Do not use an
adapter with this product.

Extension Cords

• Use only an extension cord with an undamaged,

3-prong plug.

• For 25 to 50 ft (7.6 to 15.2 m) cords, use 3-wire, 14

AWG (1.5 mm

2

) minimum.

• For up to 100 ft. (30.48 m) cord, use 3-wire, 12 AWG

(2.5 mm

2

) minimum.

Auxiliary Air Compressor (Required)

Minimum requirements 3.5 cfm @ 40 psi or 2.5 cfm @
90 psi (see manual 311763 for detailed
recommendations).

Generator Requirements (Alternate)

3500 W (3.5 KW) minimum.

Hose Size and Length

The system comes with a hose set consisting of a 3/4 in.
ID x 20 ft (25 mm x 7.6 m) material hose.

ti9165a

ti8371a

ti8568a

Advertising