5.1 Lamp Installation and Replacement

WARNING: The lamps heat up after continuous use and can burn your skin if touched. Allow lamps to cool for at least 5 minutes before
removing them.

Do not operate the UV lamp outside of the reactor. The lamps in the unit emits Ultraviolet light that can cause permanent damage to skin and
eyes. Never look at the lamps when unit is turned on.

Handle the UV lamp by the ends only. Do not touch the bulb of a lamp with your fingers. If the surface of the lamp becomes dirty, use a clean
lint-free cloth and glass cleaner to remove the dirt.

Procedure for Replacing / Installing the Ultraviolet (UV) Lamp:

1. Turn off the water supply at both ends of the system.
2. Unplug the unit.
3. Drain water from the Stainless Steel UV Chamber.
4. Allow at least 5 minutes for lamp to cool.
5. Remove the connector from the end of the UV lamp.
6. Remove the UV lamp from the quartz sleeve by gently rotating the lamp free. Be sure to hold the lamp only by the ceramic tips.
7. Insert the new UV lamp into the quartz sleeve and attach the connector.
8. Refill the UV chamber by opening the water supply just enough to fill the chamber with water.
9. Check the system for leaks.
10. Ensure that the UV lamp is operating. A purple glow should be visible on the end of the gland nut.

5.2 Cleaning the Quartz Sleeve

Mineral deposits and sediment build-up on the quartz sleeve will affect the system performance by decreasing the UV light transmitted through
the quartz sleeve into the water column.

The proper maintenance and replacement of the Sediment and Carbon Block filters supplied with the VPS1140 system will reduce the
accumulation of mineral and sediment residue on the quartz sleeve.

The quartz sleeve may be cleaned with a commercially available, non-abrasive, scale remover and a lint free cloth. Cleaning of the quartz sleeve
should be done on a regular basis to insure system performance. The amount of cleaning required will be dependant upon local water
conditions.

All traces of the cleaning solution must be fully removed from the sleeve before it is reinstalled in the system. Care should be taken to prevent
any cleaning fluid from coming into contact with the inside surface of the quartz sleeve.

Procedure for Removing / Installing the Quartz Sleeve:

1. Turn off the water supply at both ends of the system.
2. Unplug the unit.
3. Drain water from the Stainless Steel UV Chamber.
4. Allow at least 5 minutes for lamp to cool.
5. Remove the connector from the end of the UV lamp.
6. Remove the UV lamp from the quartz sleeve by gently rotating the lamp free. Be sure to hold the lamp only by the ceramic tips.
7. Remove the quartz sleeve and clean as noted above.
8. Insert quartz sleeve into the UV chamber.
9. Insert new or old UV lamp into the quartz sleeve and attach the connector.
10. Refill the UV chamber by opening the water supply just enough to fill the chamber with water.
11. Check the system for leaks.
12. Ensure that the UV lamp is operating. A purple glow should be visible on the end of the gland nut.

Advertising