307-730

CAUTION

To avoid premature wear of the pressure switch, never use more than 25 ft (7.6 m) of 1/4” ID outlet hose. When

longer outlet hose is needed, use 3/8” ID hose at a maximum of 100 ft (30 m) long. Never use 1/4” ID and 3/8” ID

hose together.
Do not use lacquer or lacquer thinner in the suction and outlet hoses supplied with this system. These fluids quickly

destroy the hose material. Use the optional chemical–resistant hoses.
See ACCESSORIES section of the manual for ordering optional hoses.

TERMS

Be sure you read and understand each of these terms be-

fore reading the rest of the manual.

WARNING: Alerts user to avoid or correct conditions

which could cause bodily injury.

CAUTION: Alerts user to avoid or correct conditions

which could damage or destroy the equipment.

NOTE: Gives additional explanation of a procedure or

helpful hints.

WARNING

Be sure all operators of this equipment read, understand,

and follow the warnings and instructions in this manual !

GENERAL SAFETY

Use extreme care not to splash paint,

contaminated

flushing water, or solvent into your eyes. Wear protective

eyewear.

Be sure the area in which you are working is well venti-

lated, to avoid a buildup of harmful paint fumes.

To reduce the risk of electric shock,

do not expose the

system to rain. Always store the system indoors. Do not

operate the pump with the base cover removed.

ELECTRICAL GROUNDING

Electrical grounding is essential to reduce the risk of an

electric shock or other serious bodily injury from static

sparking. Read and follow the grounding instructions on

page 6 of this manual.

EXTENSION MISUSE HAZARD

Do not attempt to modify the extension or roller frame, or

to use parts which are not designed for use with this sys-

tem. Use the extension only with the roller frame provided

with this system.

Improper use of the extension, roller frame, hose or roller

valve can result in component rupture or explosion and

cause serious bodily injury.

EQUIPMENT MISUSE HAZARD

This system is designed to be used at

250 psi (17.5 bar)

MAXIMUM WORKING PRESSURE . Use only compo-

nents or accessories which are designed for use with the

PT2000 System.
Any misuse of this equipment, such as modifying parts,

using incompatible paint or solvent, or using worn or

damaged parts, can cause the equipment to rupture and

result in serious bodily injury, fire, explosion and property

damage.
Never alter or modify any part of this equipment; doing so

could cause it to overpressurize or malfunction.
Check all parts of the system regularly and repair or re-

place any worn or damaged parts immediately.

AVOID POWER LINES

Avoid contacting any power lines with the extension.

Contact with power lines could cause extremely serious

bodily injury, including burns or electrocution.

HAZARD OF USING FLUIDS CONTAINING

HALOGENATED HYDROCARBONS

Never use 1,1,1–trichloroethane, methylene chloride,

other halogenated hydrocarbon solvents or fluids con-

taining such solvents in this equipment. Such use could

result in a serious chemical reaction, with the possibility

of explosion, which could cause death, serious bodily in-

jury and/or substantial property damage.
Consult your material suppliers to ensure that the fluids

being used are compatible with aluminum and zinc parts.