Greenheck Fan Hooded Propeller Roof Fans User Manual

Greenheck, Installation, operating and maintenance manual, Exhaust / supply

Advertising
background image

18

28

1

/

4

13

23

10

40

1

/

4

27

1

/

4

48 x 51

18

20

1

/

2

20

30

1

/

4

16

27

11

44

1

/

4

28

1

/

4

54 x 51

20

22

1

/

2

24

34

1

/

4

18

29

11

46

1

/

4

28

1

/

4

66 x 63

24

26

1

/

2

30

40

1

/

4

20

34

14

51

1

/

4

31

1

/

4

75 x 75

30

32

1

/

2

36

46

1

/

4

22 39

1

/

2

17

1

/

2

56

3

/

4

34

3

/

4

88 x 87

36

38

1

/

2

42

52

1

/

4

24

42

1

/

2

18

1

/

2

59

3

/

4

35

3

/

4

86 x 99

42

44

1

/

2

48

58

1

/

4

24 43

1

/

2

19

1

/

2

60

3

/

4

36

3

/

4

93 x 111

48

50

1

/

2

54

64

1

/

4

26

1

/

2

49

22

1

/

2

66

1

/

4

39

3

/

4

112 x 111

54

56

1

/

2

60

70

1

/

4

26

1

/

2

50

23

1

/

2

67

1

/

4

40

3

/

4

124 x 123

60

62

1

/

2

72

82

1

/

2

29 53

24

70

1

/

4

41

1

/

4

136 x 135

72

74

1

/

2

GREENHECK

P.O. BOX 410 SCHOFIELD, WISCONSIN 54476-0410

PH. 715-359-6171

®

READ AND SAVE THESE INSTRUCTIONS

Hooded Propeller Roof Fans
Belt Drive and Direct Drive

Installation, Operating and Maintenance Manual

Upon receiving the unit, check for any damage and report it immediately to the shipper. Also assure all accessory
items are accounted for.

To minimize installation time, most fans are shipped completely assembled. Due to shipping size limitations, hoods for larger
fans will be shipped in sections. For these fans the hood and fan components can be transported to the roof location
separately. Hood assembly should begin after the fan is attached to the roof curb. Hood assembly instructions are included
with the hood components.

Care must be taken not to bend or distort the fan panel or drive components during installation.

Part # 455305

Exhaust / Supply (

Direct Drive Sizes 18-54 - Belt Drive Sizes 20-72)

Filtered Supply

(Belt Drive Sizes Only 20 - 72)

All dimensions given in inches

W

C

B

D

A sq.

2

1

/

2

"

Tall Base Option

TB

TD

L

A sq.

Tall Base Option

Access to the motor compartment
On fan sizes 18 to 48:

- Remove two fasteners shown in fig. 1.

Carefully swing the hood 180 degrees and let it rest on
the roof. If desired, the entire hood may be removed
by removing the two additional fasteners on the
opposite side of the fan.
Use caution when handling the hood in strong winds.

On fan sizes 36 to 60 access to the motor compartment can
also be made by either:

- Removing birdscreen or filters and standing

under the hood of large fans.

- Removing one interlocking hood end section of

smaller units

Fasteners

Fig. 1

Fan

Size

A

Base

Sq.

C

B

D

TB

TD

W x L

Damper

Size

Sq.

Roof
Opg.

Sq.

Standard

Base

Tall

Base

20

30

1

/

4

16

27

11

44

1

/

4

28

1

/

4

54 x 51

20

22

1

/

2

24

34

1

/

4

18 29

11

46

1

/

4

28

1

/

4

66 x 63

24

26

1

/

2

30

40

1

/

4

20 34

14

51

1

/

4

31

1

/

4

78 x 87

30

32

1

/

2

36

46

1

/

4

22 39

1

/

2

17

1

/

2

56

3

/

4

34

3

/

4

94 x 87

36

38

1

/

2

42

52

1

/

4

24 42

1

/

2

18

1

/

2

59

3

/

4

35

3

/

4

93 x 99

42

44

1

/

2

48

58

1

/

4

24 43

1

/

2

19

1

/

2

60

3

/

4

36

3

/

4

112 x 111

48

50

1

/

2

54

64

1

/

4

26

1

/

2

49

22

1

/

2

66

1

/

4

39

3

/

4

124 x 123

54

56

1

/

2

60

70

1

/

4

26

1

/

2

50

23

1

/

2

67

1

/

4

40

3

/

4

136 x 135

60

62

1

/

2

72

82

1

/

2

29

53

24

70

1

/

4

41

1

/

4

136 x 147

72

74

1

/

2

Fan

Size

A

Base

Sq.

C

B

D

TB

TD

W x L

Damper

Size

Sq.

Roof
Opg.

Sq.

Standard

Base

Tall

Base