o

Slow Flash

N/A

Normal operation.
Standby Mode.

●

No problem.

Fast Flash

N/A

Normal operation.
Heat Mode.

●

No problem.

1 Flash

1 Flash

Lockout condition.
Ignition Failure.

●

Third failed ignition attempt. Unplug to reset
control. Contact qualified service technician.

●

Make sure manual gas shutoff valve is open.

●

If pressure is too high, the valve will not
operate.

l

●

Clean any scale buildup from burner and pilot
assembly. (Refer to page 26)

●

The spark ignitor assembly could be damaged
or broken. If so, replace assembly.

●

Bleed air from gas line. (Refer to page 28)

2 Flashes

1 Flash

Lockout condition.
Flammable Vapors Present.

●

Contact local qualified service technician.

2 Flashes

3 Flashes

Lockout condition.
FVD Interface Failure/Miswiring
(Flammable Vapor Sensor Failure).

●

Contact local qualified service technician.

3 Flashes

1 Flash

Lockout condition.
Pressure Switch Fails to Open.

●

Contact local qualified service technician.

3 Flashes

3 Flash

Lockout condition.
Pressure Switch Fails to Close.

●

Contact local qualified service agent.
Inspect vent pipe and dilution air inlet for
blockage. (Refer to “Routine Preventive
Maintenance” Section.)

4 Flashes

1 Flash

Lockout condition.
Line/Neutral Polarity Failure.

●

Check the electrical supply outlet.

4 Flashes

2 Flash

Lockout condition.
ECO Failure.

●

Contact local qualified service technician.

4 Flashes

3 Flash

Lockout condition.
False Flame (Unwanted Flame
Present).

●

Unplug to restart control. Contact local
qualified service technician.

5 Flashes

-

Vacation Mode Active

●

Select desired temperature setting.

LED Steady ON

N/A

Lockout condition.
System Error, Cycle Power.

●

Contact local qualified service technician.

30

Gas Valve LED Error Codes

CAUTION: For your safety DO NOT attempt repair of gas piping, remote control, burners, vent connectors or other safety

devices. Refer repairs to qualified service personnel.

CAUTION: Make certain power to water heater is “OFF” before removing protective cover FOR ANY REASON.

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous

operation. VERIFY PROPER OPERATION AFTER SERVICING.

Customer Service

T

roubleshooting Tips

Care and Cleaning

Operating Instructions

Installation Instructions

Safety Instructions

Advertising