High voltage, Electrical wiring – Goodman Mfg ANSI Z21.47CSA-2.3 User Manual

Page 8

Advertising
background image

8

W

HEN

 

UNIT

 

IS

 

SUSPENDED

BOARDS

 

AND

 

SHIPPING

 

BRACE

 

WILL

 

DROP

 

WHEN

 

SCREWS

 

ARE

 

REMOVED

.  T

O

 

PREVENT

 

PERSONAL

 

INJURY

, STAND CLEAR.

R

EMOVE

 

FORK

 

HOLE

 

BRACKETS

BOARDS

 

AND

 

SHIPPING

 

BRACE

 

FROM

 

BOTTOM

OF

 

UNIT

 

BEFORE

 

PLACING

 

UNIT

 

ONTO

 

CURB

.

CAUTION

To assist in determining rigging requirements, unit weights
are shown as follows:

COMPRESSOR 1

COMPRESSOR 2

CG

E

V

A

P

O

R

A

T

O

R

C

O

IL

S

A

B

C

X

D

Y

CORNER & CENTER OF GRAVITY LOCATIONS

CPG Weights

CPG Weights

(lbs)

(lbs)

15 Tons

20 Tons

Corner Weight - A

570

655

Corner Weight - B

535

535

Corner Weight - C

545

600

Corner Weight - D

510

485

Unit Shipping Weight

2270

2390

Unit Operating Weight

2155

2275

X (Inches)

65"

63"

Y (Inches)

43"

40"

DATA

NOTE: These weights are without accessories installed.

T

O

 

PREVENT

 

SEVERE

 

DAMAGE

 

TO

 

THE

 

BOTTOM

 

OF

 

THE

 

UNIT

DO

 

NOT

 

FORK

 

LIFT

 

UNIT

 

AFTER

 

WOOD

 

STRUTS

 

HAVE

 

BEEN

 

REMOVED

.

CAUTION

Bring condenser end of unit into alignment with the curb. With
condenser end of the unit resting on curb member and using
curb as a fulcrum, lower opposite end of the unit until entire
unit is seated on the curb. When a rectangular cantilever
curb is used, care should be taken to center the unit. Check
for proper alignment and orientation of supply and return
openings with duct.

R

IGGING

R

EMOVAL

T

O

 

PREVENT

 

DAMAGE

 

TO

 

THE

 

UNIT

DO

 

NOT

 

ALLOW

 

CRANE

 

HOOKS

 

AND

 

SPREADER

 

BARS

 

TO

 

REST

 

ON

 

THE

 

ROOF

 

OF

 

THE

 

UNIT

.

CAUTION

Remove spreader bars, lifting cables and other rigging equip-
ment.

ELECTRICAL WIRING

HIGH VOLTAGE !

D

ISCONNECT

 

ALL

 

POWER

 

BEFORE

 

SERVICING

 

OR

 

INSTALLING

 

THIS

 

UNIT

. M

ULTIPLE

 

POWER

 

SOURCES

 

MAY

 

BE

 

PRESENT

. F

AILURE

 

TO

 

DO

 

SO

 

MAY

 

CAUSE

 

PROPERTY

 

DAMAGE

PERSONAL

 

INJURY

 

OR

 

DEATH

.

WARNING

HIGH VOLTAGE !

T

O

 

AVOID

 

PERSONAL

 

INJURY

 

OR

 

DEATH

 

DUE

 

TO

 

ELECTRICAL

 

SHOCK

DO

 

NOT

 

TAMPER

 

WITH

 

FACTORY

 

WIRING

. T

HE

 

INTERNAL

 

POWER

 

AND

 

CONTROL

 

WIRING

 

OF

 

THESE

 

UNITS

 

ARE

 

FACTORY

INSTALLED

 

AND

 

HAVE

 

BEEN

 

THOROUGHLY

 

TESTED

 

PRIOR

 

TO

 

SHIPMENT

. C

ONTACT

 

YOUR

 

LOCAL

 

REPRESENTATIVE

 

IF

 

ASSISTANCE

 

IS

 

REQUIRED

.

WARNING

T

O

 

PREVENT

 

DAMAGE

 

TO

 

THE

 

WIRING

PROTECT

 

WIRING

 

FROM

 

SHARP

 

EDGES

. F

OLLOW

 

NATIONAL

 

ELECTRICAL

 

CODE

 

AND

 

ALL

 

LOCAL

 

CODES

 

AND

 

ORDINANCES

. D

O

 

NOT

 

ROUTE

 

WIRES

 

THROUGH

 

REMOVABLE

 

ACCESS

 

PANELS

.

CAUTION

C

ONDUIT

 

AND

 

FITTINGS

 

MUST

 

BE

 

WEATHER

TIGHT

 

TO

 

PREVENT

 

WATER

 

ENTRY

 

INTO

 

THE

 

BUILDING

.

CAUTION

For unit protection, use a fuse or HACR circuit breaker that is
in excess of the circuit ampacity, but less than or equal to the
maximum overcurrent protection device. DO NOT EXCEED
THE MAXIMUM OVERCURRENT DEVICE SIZE SHOWN
ON UNIT DATA PLATE.

Advertising