Performance Data Sheet.

SmartWater Filtration System GXSL55R Using Filter FQSLF

■ This System has been tested according to NSF/ANSI 42 and 53 for the reduction of the substances listed below. The concentration of the indicated

substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system,
as specified in NSF/ANSI 42 and 53.

■ Actual performance may vary with local water conditions.

WARNING:

Do not use with water that is microbiologically unsafe or with water of unknown quality without adequate disinfection

before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.

5

Standard No. 42: Aesthetic Effects

USEPA

Influent

Influent

Effluent

% Reduction

Min. Required

Parameter

MCL

Challenge Concentration

Average

Average

Maximum

Average

Minimum

Reduction

Chlorine

2.0 mg/L + 10%

2.00 mg/L

0.050625 mg/L

0.06 mg/L

97.52%

97.00%

>50%

T & O

Nominal Particulate**

at least 10,000 particles/mL

14,000,000 #/mL

196,666 #/mL

370,000 #/mL

99.00%

97.40%

>85%

Standard No. 53: Health Effects

USEPA

Influent

Influent

Effluent

% Reduction

Min. Required

Parameter

MCL

Challenge Concentration

Average

Average

Maximum

Average

Minimum

Reduction

Turbidity

0.5 NTU***

11 + 1 NTU***

10.5 NTU

0.125 NTU

0.30 NTU

98.80%

97.30%

0.5 NTU

Cysts

99.95% red.

Minimum 50,000 L

122,500 #/L

<1 #/L

<1 #/L

>99.99%

>99.99%

>99.95%

Asbestos

99% red.

10

7

and 10

8

;

126.5 MF/L

<.17 MF/L

<.17 MF/L

>99.99%

>99.99%

>99%

fibers >10 micrometers long

Lead, pH 6.5

0.010 mg/L

0.015 mg/L + 10%

0.150 mg/L

<0.001 mg/L

<0.001 mg/L

>99.30%

>99.30%

0.010 mg/L

Lead, pH 8.5

0.010 mg/L

0.015 mg/L + 10%

0.150 mg/L

<0.001 mg/L

<0.001 mg/L

>99.30%

>99.30%

0.010 mg/L

Mercury, pH 6.5

0.002 mg/L

0.006 mg/L ± 10%

0.006 mg/L

0.0003 mg/L

0.0005 mg/L

95.00%

91.70%

0.002 mg/L

Mercury, pH 8.5

0.002 mg/L

0.006 mg/L ± 10%

0.0059 mg/L

0.00073 mg/L

0.0018 mg/L

88.10%

69.20%

0.002 mg/L

Atrazine

0.003 mg/L

0.009 mg/L + 10%

0.0102 mg/L

0.00105 mg/L

0.0027 mg/L

89.40%

76.30%

0.003 mg/L

Lindane

0.0002 mg/L

0.002 mg/L + 10%

0.0019 mg/L

0.000035 mg/L

0.00016 mg/L

97.90%

91.80%

0.0002 mg/L

2,4-D

0.07 mg/L

0.200 mg/L ± 10%

0.2005 mg/L

0.017575 mg/L

0.064 mg/L

84.90%

69.00%

0.07 mg/L

Toxaphene

0.003 mg/L

0.015 ± 10%

0.015 mg/L

<0.001 mg/L

<0.001 mg/L

>93.30%

>93.30%

0.003 mg/L

*Tested using a flow rate of 0.78 gpm (2.95 l/min); pressure of 60 psig; pH of 7.5 ± 0.5; temp. of 68° ± 5°F (20° ± 3°C)

**Measurement in particles/mL. Particles used were 0.5–1 microns.
***NTU—Nephelometric Turbidity Units
Operating Specifications
Capacity: certified for up to 1200 gallons (4,542 l); up to six months
Pressure requirement: 35–120 psi (2.8–8.2 bar)
Temperature: 33–100°F (0.6–38°C)
Flow rate: 0.78 gpm (2.95 l/min)

Replacement Filter Canisters/Estimated Replacement Costs

FQSLF—Replacement filter canister $30–35

For replacement parts, call toll-free 800.626.2002 (U.S.),
800.663.6060 (Canada–English), 800.361.3869 (Canada–French)