Care and Cleaning

Icemaker

Light bulb
replacement

The icemaker has a light bulb in the top of the
storage bin. To replace it, open the bin door and
follow these instructions:

1. Unplug the icemaker or disconnect power.

2. Remove the 2 screws that hold the cutter grid

cover in place. Reach behind the control panel
and pull the light bulb down.

3. Replace with a 12-volt wedge base-type

bulb (automotive #917). Locate the light bulb
receptacle at the top behind the control
panel. Align the flat edge of the light bulb
with the receptacle and snap the bulb
into place.

4. Replace the cutter grid cover with the

2 screws.

5. Plug in the icemaker or reconnect power.

Vacation
and moving

To shut down the icemaker:

1. Unplug the icemaker or disconnect power.

2. Remove all ice from the storage bin.

3. Shut off the water supply.

4. Remove the 2 screws in the lower access

panel and the 2 screws from the base grille
area of the front panel support. Pull forward
to remove the lower access panel.

5. Disconnect the inlet and outlet lines to water

valve. Allow these lines to drain and then
reconnect to the valve.

6. Replace the lower access panel and screws.

Drain water from water reservoir by removing
the drain cap. Also, remove water from drain
line. Leave the door open to allow the
icemaker and water reservoir to dry out
completely.

7. Before using again, clean the icemaker and

storage bin.

IMPORTANT: Every time the icemaker is turned
off, you MUST clean the icemaker system with
the Nickel Safe Ice Machine Cleaner. See Care
and Cleaning—Icemaker system
section for
instructions.

8. Plug in the icemaker or reconnect power.

NOTE: All components of the icemaker are
permanently lubricated at the factory. They
should not require any additional oiling
throughout the normal life of the machine.

Reverse
Osmosis
system

IMPORTANT: The performance of the icemaker
may be affected when connected to a Reverse
Osmosis system. An RO system may also reduce
water pressure and affect the fill cycle, which is
dependent on time and flow. The reduced water
pressure may cause the reservoir not to fill and
flush properly during the ice making cycle.

The pressure of the water supply coming out
of a reverse osmosis system going to the water
inlet valve of the icemaker needs to be between
30 and 120 psi.

If a reverse osmosis water filtration system is
connected to your cold water supply, the water
pressure to the reverse osmosis system needs
to be a minimum of 40 to 60 psi. The reverse
osmosis system must provide 1 gal. of water
per hour to the icemaker for proper icemaker
operation.

Do not use copper tubing when the icemaker is
connected to a Reverse Osmosis water system.