MGE UPS Systems Galaxy PW User Manual

Page 29

Advertising
background image

21

■

inverse video:

When this function is selected, the text and
background colours are reversed (white
text on black or black text on white).

■

past events:

See section "logging and time-stamping".

■

battery test:

❏

the screen opposite is displayed when a

battery test is requested. It indicates the
battery charge status and the remaining
service life. A manual or automatic test
may be requested,

❏

the screen opposite is displayed during

a battery test, whether manual or automat-
ic,

❏

the screen opposite is displayed follow-

ing a positive, manual battery test,

❏

the screen opposite is displayed follow-

ing a negative, manual battery test,

❏

the screen opposite is displayed follow-

ing a positive, automatic battery test. It
indicates the time since the last test and
provides access to test settings,

❏

the screen opposite is displayed follow-

ing a negative, automatic battery test. It
indicates the time since the last test and
provides access to test settings,

❏

the screen opposite is displayed when

the user requests access to the automatic
test settings. It is possible to modify the
interval between two automatic tests,

❏

the screen opposite is displayed when

the battery test cannot be completed.

Control-panel Display

SELECT TIME OF NEXT TEST WITH KEYS

▼ ▼

CHANGE UNITS WITH

↵

↵

WEEK -- DAY -- HOUR --

confirm with key

TIME SINCE LAST TEST

WEEK -- DAY -- HOUR --

LAST BATTERY TEST RESULT NOT OK

NEW PARAMETERS YES =

▼

NO =

▼

TIME SINCE LAST TEST

WEEK -- DAY -- HOUR --

LAST BATTERY TEST RESULT OK

NEW PARAMETERS YES =

▼

NO =

▼

BATTERY TEST RESULT NOT OK

BATTERY TEST RESULT OK

TESTING BATTERY

U BATTERY =

--- V

CHARGE LEVEL

= -- %

REMAINING SERVICE LIFE

= -- MONTH

■

MANUAL TEST press key

↵

↵

■

AUTO TEST

press key

↵

↵

TEST INTERRUPTED

CHECK PRESENCE OF THE BATTERY

CHECK ALARMS

User’s Manual

Advertising