OPERATING INSTRUCTIONS

1. STOP! Read the safety information label.
2. Make sure the manual shutoff valve is fully open.
3. This gas log set is equipped with an ignition device (piezo) which automatically lights the pilot. If piezo

ignitor does not light the pilot, refer to instructions for “Match Lighting Instructions,” page 30.

4. Turn gas control knob clockwise

to the OFF position and turn ON/OFF switch to OFF position.

5. Wait (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP!

Follow "B" in the safety information label. If you don't smell gas, go to next step.

6. From OFF position, turn the gas control knob counterclockwise

to IGN position. Push in control

knob for 5 seconds. NOTE: If you are running the heater for the fi rst time, it will be necessary
to press in the control knob for 30 seconds to allow air to bleed out of the gas piping.

7. With the control knob pushed in, push in and release the piezo ignitor button to light the pilot.
8. Continue pushing the control knob in for a further 60 seconds to prevent the flame detector from

shutting off the gas while the probe is warming up. Release the control knob.

9. Turn gas control knob counterclockwise

to the ON position.

10. After the pilot has been lit for one minute, the burners can be turned on. Turn the ON/OFF switch to ON

position or adjust thermostat to desired setting.

11. If the gas logs will not operate, follow the instructions “To Turn Off Gas To Appliance” below and call

your service technician or gas supplier.

Figure 35 - Pilot

Figure 36 - Control Cover Plate for Milli-Volt

Hi/Lo Control

Ignitor Pilot Control

On/Off Switch

Piezo

TO TURN OFF GAS TO HEATER

1. Turn control knob clockwise

to OFF position to completely shut off the heater.

2. If applicable: Turn ON/OFF switch to OFF position and/or set thermostat (if present) to lowest setting.
3. If applicable: Turn off all electric power to the heater.

MILLI-VOLT/THERMOSTAT CONTROL

LIGHTING INSTRUCTIONS