Product features, Specifications – MartinLogan VENT-FREE FIREPLACE SYSTEMS 33ISDG User Manual

Page 6

Advertising
background image

6

23D8036

NATURAL GAS
Milli-Volt and T-Stat Pressure

Regulator Pressure Setting: 3.5" w.c.
Pilot Regulator: 3.5" w.c.
Gas Inlet Pressure: Max. 10 1/2" w. c.

Min. 5" w.c.

PRODUCT FEATURES

AND

SPECIFICATIONS

PROPANE/LPG

Note: An external regulator is required to reduce supply pressure to a maximum of 13" w.c.

Milli-Volt and T-Stat Pressure

Regulator Pressure Setting: 10" w.c.
Gas Inlet Pressure: Max. 13" w.c.

Min. 11" w.c.

IGNITION CONTROLS

Piezo ignitor allows ignition of the pilot without the use of matches or batteries.

Milli-Volt and T-Stat control has four (4) positions:

OFF

- All gas to the gas logs is shut off at the valve.

IGN

- Valve position to light/maintain a standing pilot.

ON

- Valve position to turn ON/OFF log set with remote switch/thermostat.

LOW/HI

- Variable position to control flame height (heat output). Both front and rear burners are in operation

to provide realistic glow and yellow flame.

PILOT

The gas log heater is fitted with a specially designed safety pilot light (ODS assembly) which senses the amount of oxygen
available in the room and shuts the gas log heater off if the oxygen level begins to drop below a satisfactory level. The
pilot can only be relit when adequate fresh air is available.

THERMAL GENERATOR

The milli-volt gas log pilot is fitted with a milli-volt generator to provide power for remote activation.

Gas Rate

Model Number

Control

Max BTU/HR

Min BTU/HR

33ISDNTG

Millivolt

28,000

19,000

33ISDNVG

T-Stat

28,000

19,000

Gas Rate

Model Number

Control

Max BTU/HR

Min BTU/HR

33ISDPTG

Millivolt

28,000

23,000

33ISDPVG

T-Stat

28,000

23,000

Advertising