The lamp is designed to project the image on the LCD
panels. When the lamp no longer functions, replace it
with a new one.

Caution:
• Do not remove the lamp immediately after using

the projector, you may get burned because of the high
temperature of the lamp.

• When you replace the lamp, press the power button

to power off, then wait for 120 seconds in stand-by
mode to allow the lamp and LCD panels to cool. Turn
off the main switch, unplug the power cord from
the outlet, and wait one hour so that the lamp is
cooled to the touch.

• Do not remove the lamp except for replacement.

Careless treatment can cause injury or fire.

• Do not touch the lamp element directly. It may break

and cause you to injure or burn yourself.

• Be sure not to drop the lamp lid screw into the pro-

jector. Also be sure not to insert metal or any flam-
mable objects, it may cause fire or electric shock. If
any objects are inserted, please unplug and contact
your dealer.

• Install the lamp securely, failure may cause a fire.
• If the light bulb part breaks, some small glass frag-

ments may fall out through the small cooling grill,
and sticks to the inside of projector or the lamp box.
When taking the lamp out, make sure to turn over
the projector and hold the handle of the lamp box to
avoid injury from the glass fragments.

• Never shake the lamp or hold it in front of your face

after removing the lamp box. The glass fragments may
fall out and cause injuries to your eyes and so on.

1. Reverse the projector gently.

2. Remove the lamp cover using the

rod provided with the optional lamp
or a rod such as a
p r e c i s i o n s c r e w -
driver in the direc-
tion of the arrow as
indicated.

3. Loosen screws (a)

u s i n g a p h i l l i p s
screwdriver (+), and
remove them.

4. Pull up the handle.

5. Hold onto the projector by the

handle as you pull out the lamp.

• Pull the lamp out of the projector

slowly. Should the light bulb be bro-
ken, glass fragments will spill out if
the lamp is pulled out too quickly.

• Once the lamp has been removed,

do not spill liquid on it, place it near
flammable objects or where chil-
dren can touch it. Otherwise, it will
cause injury or fire.

6. Insert the new lamp securely into

the projector body in the right di-
rection.

• Make sure that the two position-

ing bosses (b) fit to the lamp posi-
tioning holes before inserting the
lamp.

7. Put the handle back to the hold-

ing point.
• Make sure that the handle is

locked.

8. Tighten up the screws (a) using

a phillips screwdriver (+).

9. Close the lamp cover.

How to reset the operation time meter
Plug in the power cord, switch on the projector, and
reset lamp time by pressing the

$, % and POWER

buttons on the contro panel simultaneously.

Important:
• If the 3 buttons was not pressed at the same time,

the lamp time may not be reset.

• Please confirm the TEMP indicator illuminates

about 2 seconds and the lamp time has been
reset.

• The projector will not turn on if you do not secure

the lamp lid.

• You must reset the operation time meter after you

replace the lamp.

• Do not reset the operation time meter unless the

lamp has been replaced.

Caution:
• Do not spill liquid on the lamp or place it near flam-

mable objects or where children can touch it. Oth-
erwise, it could cause injury or fire.

• Be sure that the projector guide is firmly inserted

between the right and left lamp guides.

Interval of the lamp replacement

The interval of the lamp replacement about 1,500 hours of
consecutive use. Replacement span may differ according to
operating environment, and may be shorter than 1,500 hours.
Decreases in luminescence and/or color brightness will indi-
cate that the light source lamp needs to be replaced. When
lamp operation time exceeds 1,000 hours*

1

, the indicator

will flash alternately between green and red (while the lamp
is in operation; when the lamp is not in operation, the indi-
cator will appear red only). When the lamp has been used
for about 1,400 hours*

1

, the message “LAMP!!.” will appear

on the screen for one minute everytime the power is turned
on. When the lamp has been used for about 1,500 hours*

1,

*

2

,

the projector will automatically shut off for safety and the
power indicator light will be red. The projector cannot be
used until the lamp has been replaced and operation timer
has been reset.

Caution:
• The lamp is fragile. If broken, be careful not to cut your-

self with glass fragments.

• The replacement span of the lamp depends on the envi-

ronment. For replacement lamps, please contact your
dealer.

The projector automatically shuts off when the
lamp is used up in about 1,500 hours*

1,

*

2

and cannot

be used until the lamp is replaced and the internal
timer is reset.

*

1

) When LAMP MODE of the INSTALLATION

menu is set to STANDARD.

*

2

) When LAMP MODE is set to LOW, the duration

will be extended maximum up to 2,000 hours.

1

2

(a)

Lamp replacement

Handle

(b)

(a)

Advertising