Troubleshooting procedures, Warning – Maytag MAH8700A User Manual

Page 12

Advertising
background image

Troubleshooting Procedures

!

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to washer before servicing, unless
testing requires power.

16026882 12 June

2006

RPL 16026127

©2006 Maytag Services

Diag.

Code

Description

Trigger

Action to be

taken

15 Stuck

Key

A key is sensed

to be pressed

more than 30

seconds, the key

will be assumed

to be stuck.

Display "E2". See
LED/Switch Test.

Check connection
of keypad to
control board.
Replace console if
necessary.

17

Door/Lid

switch was

not seen

open since

the last two

final spins

The door has not

been opened

after two

complete wash

cycles. Door

switch was not

seen open since

the last two final

spins.

Will display "od". If
door open sensed,
error will clear.
Check door lock.

18

Detected

door lock

switch open
during cycle

when not

expected.

Open door lock

switch with

motor running.

Check for loose
wire connections.
Clear the
diagnostic code
and recheck; if
reoccurs, see
Door Lock Test

.

Check door lock
system. See
Board Output
Test

. Check the

output voltage of
door lock coil. If
normal, change
door lock switch. If
not normal, change
Machine Control
Board.

19-21

Not Used

22

Door/lid

switch

detected

open during
cycle (when

not paused).

Door switch is

read as open

and the door

locked switch is

read as locked.

See Door Lock
Test

“Troubleshooting
Procedures”.

23-24

Not Used

25

Motor tach

signal exists

without motor

running.

Tach signal

exists without

torque command

or when not

expected.

Displays "bE".
Replace Motor
Control Board.

26-28

Not Used

29

Sump

thermistor

failure

(Optional)

Abnormal

high/low temp or

ohm resistance

seen

Displays " tE".
- Loose or pinched
wires.
- Bad sump
thermistor.

30-33

Not Used

Diag.

Code

Description

Trigger

Action to be

taken

2E

Motor Drive

failure

(Locked, Hall

sensor fault)

Machine control

is attempting to

drive the motor

but is not seeing

any tach

response. Visual

check shows

motor is not

moving.

Display “E3
Evaluate wire
harness for loose
or unhooked
connections. If
machine has
separate motor
control, perform
self diagnostic
motor test. See
Board Output
Test

”.

34

System

Relay failure

Machine control

does not see

relay open when

it should.

Display "Sr".
Replace machine
control board.

35

Not Used

3E

Motor failure

(Over

current)

Over Current is

detected. Motor

won't turn.

Displays
"3E".Check the
motor windings,
the speed sensor,
wiring connections,
or Control Board.

40-49

Not Used

91

Voltage for

motor control

bus is over

specified limit

Voltage for motor

control bus is

over limit

Display
"2E".Replace
Machine Control
Board.

92

Voltage for

motor control

specified limit

Voltage for motor

control bus is

under specified

limit.

Display
"2E".Replace
Machine Control
Board.


Exit Service Mode
To exit:

1) Press

Chime

and Extra Rinse keys for 3

seconds again, or

2) Press

the

Power Off

key, or

3) Unplug the machine. After five (5) minutes of

inactivity (user key presses) in Service Mode,
the machine will exit the Service Mode and
resume normal operations. Pressing the Power
Off

key will completely exit Service Mode. If a

cycle is running, cancel the cycle. Pressing the
Rotary Selector

knob while running a test will

pause the individual test, while remaining in
Service Mode

. A power loss during Service

Mode

will cancel this mode.