Section 4

Maintenance

Disassembling the Dispenser Parts

For Bin Cleaning

WARNING

Unplug unit before servicing or cleaning.

Ice dispenser bin contains moving parts that can move
at any time and will cause injury if hands are in the
way.

1

Inside the dispenser, rotate the agitator arm so the
paddle wheel pin handle is pointing up, toward
the ceiling.

2

Un-clip the hand-removable paddle wheel pin
from the agitator…

Paddle

wheel

pin

Paddle

wheel

pin

handle

3

…Then remove the paddle wheel pin by firmly
rotating the pin and pulling upward.

Paddle

wheel

hub

Paddle

wheel

pin

handle

4

Push the agitator bar toward the back of the bin
until agitator is free of the paddle wheel hub.