OWNER’S MANUAL

CLOSED

OPEN

MAINTENANCE

AND REPAIRS

WARNING: Only a qualified

electrical service person should

service and repair the alternator

on this generator. Use only factory

approved replacement parts.

HIGH ALTITUDE OPERATION

This generator will not perform well at high

altitudes without proper adjustment. See

engine owner’s manual for details.

ADDING ELECTRICAL

LOADS

IMPORTANT: Do not overload generator.

Make sure total wattage of all electrical loads

does not exceed rated wattage of generator.

Overloading may shorten generator life. It

could also cause internal damage to genera-

tor. Overloading will trip circuit breaker.
IMPORTANT: (All models except

MGR2900A) Keep voltage selector switch

in the 120 VOLT ONLY position if only

powering 120V items. Only move switch

to 120 + 240 VOLT position if powering

240V items.
1. Check items to be powered. Their

nameplate lists their wattage ratings.

Note: The wattage ratings for some

electrical motors are misleading. They

may require up to three-times their

rated wattage to start. You must figure

total electrical load wattage. Make sure

total wattage of all electrical loads does

not exceed rated wattage of generator.

See Determining Electrical Load For

Generator, page 9.

2. Start engine. Let engine reach full

speed.

3. Connect electrical loads one at a time.

If the load consists of electric motors,

start them first. Always start the largest

first. Start each motor individually.

DISCONNECTING ELECTRIC

LOADS

Remove electrical loads one at a time. Re-

move voltage sensitive items first. Voltage

sensitive items include TVs, VCRs, and

other home electronic items.

STOPPING ENGINE

IMPORTANT: The engine speed is preset.

The throttle is locked in preset position. Do

not adjust throttle.
Follow the steps below to stop engine.
1. Remove all electrical loads from genera-

tor (see Disconnecting Electrical Loads).

Remove electrical loads one at a time.

2. Let engine run for two or three minutes

after removing electrical loads. This

lets engine cool slightly.

3. Turn engine switch to the OFF position

(see Figure 18).

4. Turn fuel valve lever off except on Model

MGR6000I. Do this by moving valve

lever fully to the left (see Figure 19).

Figure 18 - Engine Switch In OFF

Position

Figure 19 - Fuel Valve Lever Off (Model

MGR4500I Shown)

Fuel Valve Lever

(Off Position)

OFF

ENGINE SW

ON

OPERATION

Continued

IMPORTANT: Keep generator level when

servicing. Never turn generator upside down

or stand it on end to service.
Note: We supply the engine owner’s manual

with generator. Refer to that manual for

questions concerning engine maintenance

and repairs.
Non-engine parts require little maintenance.

Keep generator clean. Use a damp cloth to

clean outside surfaces. Never use water to

clean generator. Water can cause damage to

internal parts. Use vacuum to clean air inlet

and outlet louvers of alternator.

CAUTION: Shut off generator

before performing maintenance.

CAUTION: The engine speed

is preset. The throttle is locked

in preset position. Do not adjust

throttle. Preset position lets en-

gine run at 3600 RPM under load.

The engine must maintain 3600

RPM for generator to create cor-

rect voltage. Running engine at

lower speeds will damage genera-

tor and powered items.