Portable gasoline generators, Troubleshooting, Storage – Master Lock MGR2900A User Manual

Page 14: Servicing the engine, Technical service

Advertising
background image

14

118679

PORTABLE GASOLINE GENERATORS

R

TROUBLESHOOTING

WARNING: Only a qualified electrical service person should service

and repair generator. Use only factory approved replacement parts.

POSSIBLE CAUSE

1. Loss of residual magnetism

2. Winding short circuit or loose

connections

3. Defective rotor diode

4. Defective capacitor

1. Engine speed too low

2. Defective rotor diode

3. Partial short circuit in winding

4. Defective capacitor

1. Engine speed too high

1. Defective rotor diode

2. Electrical load too high

3. Engine not running properly

OBSERVED PROBLEM

No voltage when starting generator with no

electrical load

Voltage is less than normal voltage with no

electrical load

Voltmeter reading more than 10% high with

no electrical load

Voltmeter reading correct with no electrical

load, but more than 10% low when electrical

load is added

REMEDY

1. Apply 12-volt battery to capacitor ter-

minals for 2-3 seconds

2. Check resistance of coils (see Electrical

Component Specifications, page 15)

3. Replace both diodes on rotor

4. Replace capacitor

1. Set engine speed to 3800 RPM (63 Hz)

with no load

2. Replace both diodes on rotor

3. Check resistance of coils (see Electrical

Component Specifications, page 15)

4. Replace capacitor

1. Set engine speed to 3800 RPM (63 Hz)

with no load

1. Replace both diodes on rotor

2. Do not overload generator

3. Contact an authorized engine service

center

STORAGE

Note: For additional help, visit DESA

Specialty Products’™ technical service

web site at

www.desatech.com.

www.desatech.com

Note: See engine owner’s manual for engine troubleshooting.

SERVICING THE

ENGINE

Robin parts and services should be handled

by your nearest authorized engine service

firm. Visit:
www.robinamerica.com
or call Robin direct:

1-800-277-6246

IMPORTANT: Keep generator level while in

storage. Never store generator upside down

or standing on end.
Note: We supply the engine owner’s manual

with generator. Refer to that manual for

questions concerning engine storage.

WARNING: The muffler be-

comes very hot during operation.

The muffler remains hot for a

while after shutdown. Let engine

cool before storing.

WARNING: Remove all fuel from

fuel tank before storing generator.

Store fuel in approved container.

Store fuel in a well-vented area free

of open flames or sparks.

Use a fuel additive, such as STA-BIL

®

or an

equivalent, when storing generator with fuel

in fuel tank. This will minimize fuel gum

deposits from forming in engine.
Cover and store generator in a clean, dry

place. Do not expose generator to extreme

high or low temperatures during storage.

TECHNICAL

SERVICE

You may have further questions about as-

sembling, operating, or maintaining this

product. If so, you can visit our Technical

Service web site at

www.desatech.com

or

contact our Technical Service Department

at 1-800-858-8501 (English Only). You may

also write to:
DESA Specialty Products™

ATTN: Technical Service Specialty Products

P.O. Box 90004

Bowling Green, KY 42102-9004
When contacting DESA Specialty Prod-

ucts™, have ready
• Your Name
• Your Address
• Your Phone Number
• Model Number of Product
• Serial Number
• Date of Purchase (Include copy of receipt

for written requests).