66

••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••

RS-232C terminal

RS-232C

1

6 9

5

2

3

4

5

RXD

TXD

DTR

GND

Receiving Data

Transmission Data

Data Terminal Ready

Signal Ground

Pin NO. Letters

Letters

Pin NO.

Transmition Contents

Transmition Contents

6

7

8

DSR

RTS

CTS

Data Set Ready

Transmission

Requirement

Transmission Clear

RS-232C cable

Please use the following RS-232C Crossover cable to connect your personal computer to the Unit.

FRAME

D-SUB 9 pin (unit)

D-SUB 25 pin(Personal computer)

FG
TXD
RXD
RTS
CTS
DSR
GND
DTR

1
2
3
4
5
6
7

20

RXD

TXD

DTR

GND

DSR

RTS
CTS

2
3
4
5
6
7
8

1) When RS-232C terminal of personal
computer is D-SUB 25 pin

D-SUB 9 pin

D-SUB 9 pin

FRAME

FRAME

RXD
TXD
DTR
GND
DSR
RTS
CTS

2
3
4
5
6
7
8

RXD

TXD

DTR

GND

DSR

RTS
CTS

2
3
4
5
6
7
8

2) When Pesonal cpmputers RS-232C
terminal is D-SUB 9 pin

Setting the communicating mode

The settings can be made on RS-232C SETTING of the <REAR TERMINAL> menu. Set the Unit and the modem or a personal
computer with same settings. Please refer to the diagram for possible setting rate.

1

2

3

4

5

TRANSMISSION

RATE

DATA BIT LENGTH

PARITY BIT

STOP BIT

DELIMITER

1200/2400/4800/

9600

8 BIT/7 BIT

NONE/ODD/EVEN

1 BIT/2 BIT

CR/CR•LF

Synchronization

Name on Menu

Asynchronous

1

2

3

X control

S parameter

CS-RS hamd-shake

Not available

Not available

Available

Synchronization

Name on Menu

# Set other functions on the personal
computer as shown below.

Transmission rate at
the data received/
sent

Data bit length

Parity bit setting

Stop bit length

Line feed setting

Please note that the RS-232C interface (located on the back of the unit) does not function while the unit is in commu-

nication mode.

Command code and status

Operation and setting of this unit by a personal computer is executed by command codes and error codes.

Delimeter

(sending) #1

Delimeter

(receiving) #2

Parameter 1

Parameter n

Command code

Status

Parameter 2

Parameter 1

Parameter n

Parameter 2

,

,

,

• • • • • • • • • •

• • • • • • • • • •

• • • • • • • • • •

• • • • • • • • • •

1) Command : an order from a personal computer to the unit

2) Command : a reply from the unit ( indicated on a personal computer)

,

,

,

#1: If you set the DELIMITER setting to "CR" on the RS-232C setting menu,
input a Carrige return code (0DH).
If you set the DELIMITER setting to "CR • LF" on the RS-232C setting menu,
input a carrige return code (0DH) and a line

****

code (0AH).

#2: If you set the DELIMITER setting to "CR" on the RS-232C setting menu,
output a Carrige return code (0DH).
If you set the DELIMITER setting to "CR • LF" on the RS-232C setting menu,
output a carrige return code (0DH) and a line

****

code (0AH).

Make sure to send commands in an interval of 0.1 second.

Example of Command operation

PW1

CR

RC

EX

CR

CR

Example 1) Turn the Unit on.( when DELIMITER is set to "CR" on the RS-232C setting menu)

Command from

personal computer

Replied status code from uint
to a personal computer

Meaning

Sending a command to turn the Unit on.

The unit received a command and executed.

The unit received a command.

Connecting to a personal computer

Command code

Connecting to a personal computer (continued)

/ Command codes