31

D

ESIGN

S

PECIFICATIONS

MS9500 Series Specifications

O

PERATIONAL

Light Source Visible Laser Diode 650 nm

Laser Power: Less than 1 mW (peak)

Depth of Scan Field:

0 mm - 203 mm (0" - 8") for
0.330 mm (13 mil) bar code at default settings

Scan Speed: 72 scan lines per second

Scan Pattern: Single scan line

Minimum Bar Width: 0.127 mm (5.0 mil)

Long Range: 0 mm – 279 mm ± 51 mm (0" – 11" ± 2")

Infrared Activation:

Short Range: 0 mm – 102 mm ± 25 mm (0" – 4" ± 1")

Decode Capability:

Autodiscriminates all standard bar codes for others call
a Metrologic service representative

System Interfaces:

RS232, PC Keyboard Wedge, Stand-Alone Keyboard,
RS485 IBM 468X/469X, Light Pen Emulation, Laser
Emulation, RS232 with DSR, Low Speed USB (Serial
Emulation or Keyboard Emulation
), Full Speed USB

Print Contrast: 35% minimum reflectance difference

Number Characters

Read:

Up to 80 data characters (Maximum number will vary
based on symbology & density
)

Roll, Pitch, Yaw: 42°, 68°, 52°

Beeper Operation: 7 tones or no beep

Green* LED laser on, ready to scan

Red* LED good read

ON, CodeGate button is inactive

Visual Indicators:

Default Settings

Yellow LED

(MS9540 Only) OFF, CodeGate button is active

* In

some

custom units, the standard green LED has been replaced with a blue LED

and the red LED has been replaced with a white LED.

Specifications are subject to change without notice.