Scanner and cable terminations, Scanner pinout connections – Metrologic Instruments Voyager MS9500 Series User Manual
Page 42

38
1
10
S
CANNER AND
C
ABLE
T
ERMINATIONS
Scanner Pinout Connections
MS95
x0-41
RS232 and Light Pen Emulation
Pin
Function
1 Ground
2
RS232 Transmit Output
3
RS232 Receive Input
4 RTS
Output
5 CTS
Input
6
DTR Input/LTPN Source
7 Reserved
8 LTPN
Data
9 +5VDC
The MS9520 and MS9540
scanner interfaces terminate to
a 10-pin modular jack.
The serial # label indicates the
interface enabled when the
scanner is shipped from the
factory.
10 Shield
Ground
MS95
x0-47
Keyboard Wedge and Stand-Alone Keyboard
Pin
Function
1 Ground
2
RS232 Transmit Output
3
RS232 Receive Input
4 PC
Data
5 PC
Clock
6 KB
Clock
7 PC
+5V
8 KB
Data
9 +5VDC
10 Shield
Ground
MS95
x0-11 RS485
Pin
Function
1 Ground
2
RS232 Transmit Output
3
RS232 Receive Input
4 RTS
Output
5 CTS
Input
6 DTR
Input
7 IBM
B-Transmit
8
IBM A+ Receive
9 +5VDC
10 Shield
Ground
Applicable for IBM
®
host applications.