Walk Test Mode
A walk test is performed in order to determine the lens coverage pattern of the
detector – see Figure B.2. Walk Test mode cancels the delay time between
detections, enabling you to perform an efficient walk test.

To perform a Walk Test.

1.

Place the Mode jumper over pins 1 & 2.

2. Walk across the scope of the detector according to the detection pattern

selected.

3. Confirm that the LED activates and deactivates accordingly. Wait five

seconds after each detection before continuing the test.

4. After completing the walk test, remove the jumper and place it over one

pin for storage – see Mode Jumper Safeguard.

LED Indication
The LED indicator is lit twice every time a transmission is made. To enable or
disable LED indication, refer to Table
B.4 below.
Table B.4: LED Indication Settings

The LED should only be disabled after successfully walk testing the
detector.

Mode Jumper Safeguard
During normal operation, the Mode jumper should be placed over one pin for
storage. When the mode jumper is placed over two pins, the detector is either in
Radio or Walk Test Mode. As a precaution, these modes are limited to three
minutes. After three minutes have expired, the detector switches back to normal
operation. If this happens, you can reset a mode by removing and replacing the
mode jumper.

TECHNICAL DATA
Antenna:

Built-in

Whip

Frequency:

868.35MHz FM

Power:

3.6V ½ AA Lithium Battery

Current Consumption:

30mA (transmission),

12µA

(standby)

Pyroelectric Sensor:

Dual Element

Maximum Coverage:

12 x 12m

Pulse Count:

1, 2, 3 or Adaptive

LED Indicator:

Selectable

Adaptive Temperature Compensation
RFI Immunity:

30V/m

Operating Temperature:

-10 to 60°C

Fire Protection:

ABS Plastic Housing

Dimensions:

110 x 60 x 45mm

LED Indication

MS845

Disabed

DIP-Switch 1 OFF

Enabled

DIP-Switch 1 ON