Ethernet fieldbus gateways – Moxa Technologies MOXA V91 User Manual

Page 50

Advertising
background image

40

w w w. m o x a . c o m

i n f o @ m o x a . c o m

Serial-to-Ethernet Solutions

Ethernet Fieldbus Gateways

>

3

MGate™ MB3170

MGate™ MB3170-T

MGate™ MB3170I

MGate™ MB3170I-T

MGate™ MB3270

MGate™ MB3270-T

MGate™ MB3270I

MGate™ MB3270I-T

MGate™ MB3180

MGate™ MB3280

MGate™ MB3480

Ethernet Interface

Number of Ports

2 (1 IP)

2 (1 IP)

2 (1 IP)

2 (1 IP)

1

1

1

Speed

10/100 Mbps

10/100 Mbps

10/100 Mbps

10/100 Mbps

10/100 Mbps

10/100 Mbps

10/100 Mbps

Connector

RJ45

RJ45

RJ45

RJ45

RJ45

RJ45

RJ45

Magnetic Isolation

Protection

1�5 KV

1�5 KV

1�5 KV

1�5 KV

1�5 KV

1�5 KV

1�5 KV

Serial Interface

Number of Ports

1

1

2

2

1

2

4

Serial Standards

RS-232/422/485

RS-232/422/485

RS-232/422/485

RS-232/422/485

RS-232/422/485

RS-232/422/485

RS-232/422/485

Connectors

RS-232: DB9-M; RS-422/485: Terminal Block

DB9-M

DB9-M

DB9-M

DB9-M

DB9-M

ESD Protection

15 KV

15 KV

15 KV

15 KV

15 KV

15 KV

15 KV

RS-485 Data Direction

Control

ADDC®

ADDC®

ADDC®

ADDC®

ADDC®

ADDC®

ADDC®

Serial Communication

Parameters

Data Bits: 7, 8; Stop Bits: 1, 2; Parity: None, Even, Odd, Space, Mark

Parity

None, Even, Odd, Space, Mark

Flow Control

RTS/CTS, DTR/DSR (RS-232 only)

Baudrate

50 bps to 921�6 Kbps

Software

Operation Modes

RTU Slave, RTU Master, ASCII Slave, ASCII Master

Utilities

MGate™ Manager Suite for Windows 98, ME, NT, 2000, XP, 2003, Vista

Smart Routing

Serial Redirection

---

---

---

Priority Control

---

---

---

Ethernet Protocol

---

---

---

---

---

---

---

Serial Protocol

---

---

---

---

---

---

---

Physical Characteristics

Housing

Plastic

Plastic

Plastic

Plastic

Metal

Metal

Metal (IP30)

Dimensions

29 x 89�2 x 118�5 mm

22 x 52 x 80 mm

22 x 77 x 111 mm

35�5 x 103 x 158 mm

Environmental Limits

Operating Temperature

0 to 55°C or -40 to 75°C

0 to 55°C

0 to 55°C

0 to 55°C

Operating Humidity

5 to 95% RH

5 to 95% RH

5 to 95% RH

5 to 95% RH

5 to 95% RH

5 to 95% RH

5 to 95% RH

Storage Temperature

-40 to 85°C

-40 to 85°C

-40 to 85°C

-40 to 85°C

-20 to 85°C

-20 to 85°C

-20 to 85°C

Power Requirements

Input Voltage

12 to 48 VDC

12 to 48 VDC

12 to 48 VDC

12 to 48 VDC

12 to 48 VDC

12 to 48 VDC

12 to 48 VDC

Power Connector

Terminal block

Terminal block

Terminal block

Terminal block

Power jack

Power jack and terminal block

Regulatory Approvals

EMC

CE (EN55022 Class A and EN55024), FCC Part 15 Subpart B Class A

Safety

UL (UL60950-1), TÜV (EN60950-1)

Hazardous Location

UL/cUL Class 1 Division 2 Groups A, B, C, D; ATEX Class 1 Zone 2

---

---

---

Shock

IEC 60068-2-27

---

---

---

Freefall

IEC 60068-2-23

---

---

---

Vibration

IEC 60068-2-6

---

---

---

Marine

DNV

---

---

---

EMS

EN61000-4-2 (ESD): Level 3

EN61000-4-3 (RS): Level 3

EN61000-4-4 (EFT): Level 4

EN61000-4-5 (Surge): Level 3

EN61000-4-6 (CS): Level 3

EN61000-4-8: Passed

EN61000-4-11: Passed

EN61000-4-12: Passed

EN61000-4-2 (ESD): Level 2

EN61000-4-3 (RS): Level 2

EN61000-4-4 (EFT): Level 2

EN61000-4-5 (Surge): Level 2

EN61000-4-6 (CS): Level 2

EN61000-4-8: Passed

EN61000-4-11: Passed

EN61000-4-12: Passed

Reliability

Warranty

5 years (see www�moxa�com/warranty)

Ethernet Fieldbus Gateways

Ethernet Fieldbus Gateways

Advertising