Vermont Castings Jefferson Vent Free Gas Heater

Install ON/OFF Switch

(R Models only)

The switch assembly parts are found in the parts bag.
1. Attach switch assembly to left rear side of stove

shroud using two screws and existing holes in
shroud. (Fig. 17)

2. Run wires down back of stove, under bottom of rear

shroud to valve.

3. Attach wires to valve terminals. (Fig. 18)

Thermostat Wire / Gauge

Maximum Run

18

40 feet

20

25 feet

22

16 feet

Thermostat Connection (optional)

(R Models only)

1. Install the wall thermostat in the desired location and
run the wires to the stove location. Terminate these
leads with 1/4” female connectors.

2. Connect the thermostat wires to the valve. (Fig. 18)

Lava Rock

ST224

Fig. 15 Install lava rock and upper logs.

4

5

ST225

Fig. 16 Completed log installation.

Use only a thermostat rated for 500 millivolts. Do
not use low voltage (24V) thermostats.

Check the table below for the appropriate gauge
thermostat wire to use for the length of lead required in
your installation.

Existing
Holes

Switch
Assem-
bly

Screws

ST315

Fig. 17 Attach switch assembly to rear shroud.

TP

TH

TPTH

ST228

Fig. 18 Attach switch wires to valve

.